background image

Signal Conectors Kit KCS-300

E

ng
lis

h

6 | CVW300 

For any detailed information about the pin functions, 
please refer to the CVW300 user manual.

3 TERMINALS CRIMPING 

INSTRUCTIONS

Wire Sizes / Crimping Tool Recommendations

5.1 mm

0.5 ... 1.4 mm

2

 / 20 ... 16 AWG

Recommended crimping tool: TE 58529-1.

The correct wire crimping is shown below:

Wire strand ends must 

be visible in this area

Wire strands and insulation shall 

both be visible 

Ends of insulation 

barrel must be 

wrapped around 

wire insulation 

leaving no sharp 

points to damage 

rubber wire seal

0.25 mm max-0.13 mm 

min front bellmouth

0.25 mm max cutoff tab

0.13-0.75 mm 

rear bellmouth

Wire barrel shall be closed 

at seam with no strands 

protruding of showing

4 ASSEMBLY PROCEDURE

Before assembling, the wedge lock must be in the open, 
or as-shipped, position.

Wire seal

Mating seal

Diaphragm

Retention 

fingers

Contact 

(partially inserted)

Wedge lock (shown 

in open position)

The plug must be assembled as it follows:

1.  To insert a contact, push it straight into the 

appropriate circuit cavity as far as it will go.

2.  Pull back into the contact wire with a force of 4.45 to 

Summary of Contents for CVW-300

Page 1: ...Conectors Kit KCS 300 Kit de Conectores de Se al KCS 300 Kit de Conectores de Sinal KCS 300 CVW 300 Assembling Guide Gu a Montage Guia de Montagem Motors Automation Energy Transmission Distribution Co...

Page 2: ......

Page 3: ...DURE 7 NDICE 1 CONTENIDO DEL PAQUETE 8 2 FUNCIONES DE LOS TERMINALES DE LOS CONECTORES 8 3 INSTRUCCIONES PARA CRIMPADO DE LOS TERMINALES 9 4 PROCEDIMIENTO DE MONTAJE 9 5 PROCEDIMIENTO DE DESMONTAJE 10...

Page 4: ...aci n el ctrica antes de proceder a cualquier trabajo en este equipo Solamente profesionales calificados pueden efectuar la instalaci n y mantenimiento Obedezca las normas nacionales y locales as como...

Page 5: ...ONNECTORS PIN FUNCTION XC9 Black XC10 Gray Pin Function Pin Function 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9 15 V 10 DI3 10 DO2 11 DI4 11...

Page 6: ...wrapped around wire insulation leaving no sharp points to damage rubber wire seal 0 25 mm max 0 13 mm min front bellmouth 0 25 mm max cutoff tab 0 13 0 75 mm rear bellmouth Wire barrel shall be closed...

Page 7: ...ides 4 Slide the wedge lock into the housing until it is flush with the housing Wedge lock flush with housing 5 DISASSEMBLY PROCEDURE The plug must be disassembled contacts removed as it follows 1 Ins...

Page 8: ...UNCIONES DE LOS TERMINALES DE LOS CONECTORES XC9 Negro XC10 Gris Terminal Funci n Terminal Funci n 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9...

Page 9: ...ta rea Los alambres y el aislamiento deben estar visibles Las extremidades del cilindro aislante deben envolver al aislamiento del alambre sin puntas que puedan da ar el sellado de goma del alambre 0...

Page 10: ...ios deber ser cerrada la tapa frontal de cierre Traba de apriete para asentar la wedge lock ambos lados 4 Apriete la tapa frontal de cierre en direcci n al conector hasta trabarla Wedge lock nivelada...

Page 11: ...Kit de Conectores de Se al KCS 300 CVW300 11 Espa ol Aba da wedge lock Para m s detalles acerca de los conectores consulte www te com...

Page 12: ...ntagem 2 FUN ES DE CADA PINO DO CONECTOR XC9 Preto XC10 Cinza Pino Fun o Pino Fun o 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9 15 V 10 DI3 10...

Page 13: ...s nesta rea Fios e isolamento devem estar vis veis As extremidades do cilindro isolante devem envolver o isolamento do fio sem pontas que possam danificar a veda o de borracha do fio 0 25 mm m x 0 13...

Page 14: ...ar o fio para tr s a b c 3 Ap s todos os contatos necess rios terem sido inseridos a tampa frontal de travamento deve ser fechada Trava de aperto para assentar wedge lock ambos os lados 4 Aperte a tam...

Page 15: ...5 Portugu s 3 Enquanto gira o cabo de um lado a outro em meia volta um quarto de volta em cada dire o puxe tire suavemente o cabo at que o terminal esteja removido Aba da wedge lock Para maiores detal...

Page 16: ...NOTES NOTAS ANOTA ES...

Page 17: ...NOTES NOTAS ANOTA ES...

Page 18: ...NOTES NOTAS ANOTA ES...

Page 19: ......

Page 20: ...03152018 00 12975711 WEG Drives Controls Automa o LTDA Jaragu do Sul SC Brazil Phone 55 47 3276 4000 Fax 55 47 3276 4020 S o Paulo SP Brazil Phone 55 11 5053 2300 Fax 55 11 5052 4212 automacao weg net...

Reviews: