Introduction 

Thank you for purchasing the Foamstream L12!  

 

IT IS IMPORTANT THAT ALL OPERATORS READ AND 

UNDERSTAND THESE INSTRUCTIONS BEFORE USING 

THE MACHINE 

 

Having read these instructions, the operator will: 

 

Understand how the L12 works 

 

Identify key components in the L12 

 

Know  how  to  carry  out  pre-start  and  start-up 

procedures 

 

Observe safe operating practices 

 

Be able to effectively operate the L12 

 

Be able to shut down and clean the L12 

 

Be  able  to  perform  basic  maintenance  and 

troubleshooting tasks 

 

PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE 

FOR FUTURE REFERENCE 

 

3

 

Important information 

The  following  PPE  (Personal  Protective  Equipment)  are 
recommended when operating the L12: 

 

Eye 

protection 

is 

required 

when 

handling 

Foamstream® concentrate 

 

Gloves are required as the lance assembly will get hot 

 

Safety  Footwear  suitable  for  working  in  the  areas 
concerned is recommended 

 

No  specific  protective  clothing  is  required,  although 
use of overalls and a HI-Viz vest is suggested as best 

practice. 

 

IT IS THE RESPONSIBILITY OF THE OPERATOR TO WEAR 

APPROPRIATE PPE 

 

Never operate the machine without checking that there are 
adequate  supplies  of  clean  petrol/gasoline,  clean  diesel, 

clean  water,  and  clean  Foamstream®  concentrate  in  the 
appropriate tanks. 

 
The L12 produces 

VERY HOT

 water. This can cause serious 

burns and injury if used incorrectly. 

 
Never point the lance at people or animals as this machine 

can operate at high temperatures and high pressures. 
 

All  personnel  operating  a  L12  machine  must  be  deemed 

competent to do so and must be adequately trained. A copy 
of the training record is available on demand. 

 

Always check the L12 for any damage before use.  Damaged 

cables, hoses or connections must be reported immediately, 

and the machine taken out of use until repairs have been 
completed.  

 
Use  only  genuine  Weedingtech  spare  parts  and 

Foamstream®  consumables.  This  will  ensure  the  best 

performance of your machine and maintain the warranty of 
the unit. 

 
The L12 must never be modified, safety interlocks bypassed, 

or  settings  adjusted  (unless  specified  in  these  guidance 

notes) 

without Weedingtech’s written consent.

 

 

Ensure  that  the  L12  is  placed  in  an  area  where  there  is 
adequate ventilation when in use. 

Summary of Contents for Foamstream L12

Page 1: ...EPA Est No 94946 GBR 1 USER MANUAL For L12 019 and above ENGLISH EU USA 15 01 2020 ISSUE 4...

Page 2: ...L12 User manual English EU USA 15 01 2020 ISSUE 4...

Page 3: ..._________________ 15 8 2 BOILER SWITCH __________________________________________ 15 8 3 THERMOSTAT ___________________________________________ 15 8 4 TACHOMETER ______________________________________...

Page 4: ...en if a door or window is open ONLY USE IN A WELL VENTILATED AREA Do not use the L12 in potentially explosive atmospheres 1 3 Electric Shock Hazards WARNING Do not operate the L12 s electrical compone...

Page 5: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 5...

Page 6: ...ggested as best practice IT IS THE RESPONSIBILITY OF THE OPERATOR TO WEAR APPROPRIATE PPE Never operate the machine without checking that there are adequate supplies of clean petrol gasoline clean die...

Page 7: ...ees centigrade the indicator light goes green indicating that it is hot enough for weeding The water flows from the boiler 12 l m 12 bar 3 1 gpm 174 PSI and a venturi mixer opens to allow Foamstream c...

Page 8: ...03 with light WIDTH mm ft 1040 3 42 DEPTH mm ft 980 3 22 or 1950 6 40 with tank WEIGHT kg lbs 360 794 EMPTY 425 937 FULL WATER 780 LITRES 206 GAL DIESEL 32 LITRES 8 45 GAL PETROL GASOLINE 6 1 LITRES...

Page 9: ...ion main switch Cold and Hot boiler on 2 Engine Honda GX390 with speed fixed 3 Water tank 780 litres 206 gal as standard Not represented 4 Lance Not represented 5 Feet forklift slots Forklift can also...

Page 10: ...m and can be used to kill larger weeds Foam cover and hence heat retention on weeds is easier to achieve on prostrate plants that are near the ground Tall plants should be trodden down either by foot...

Page 11: ...ecies and their size 5 3 Caution poisonous weeds Some poisonous weeds such as common ragweed Senecio jacobaea may still be attractive to animals after treatment with Foamstream When treating any area...

Page 12: ...y a blanket of foam The density of the plants and foliage is a very important aspect for the operator to be aware of as this also impacts on the speed of operation It should be noted As the height and...

Page 13: ...return hose and water level sensor are connected Pipe hose routes are clear of sharp edges and hot surfaces There are no signs of leaks from any pipe or connection Petrol gasoline tank is full of cle...

Page 14: ...ill come out Turn the boiler switch to ON position 3 on Figure 7 The switch will illuminate green and the boiler will heat up whenever the trigger is pressed The boiler is only active when the trigger...

Page 15: ...nce keep the trigger pressed and wait for up to 1 minute 8 3 THERMOSTAT The thermostat indicates the water temperature at the outlet of the boiler it can be switched from Celsius to Fahrenheit 8 4 TAC...

Page 16: ...mpletely In the above conditions whereby the machine has run low on input fluids the user simply has to re fill the required fluids and then can restart the machine as usual The below conditions indic...

Page 17: ...ver the vegetation the required volume of hot water and foam may not have penetrated or been applied correctly Total vegetation control will not have been achieved 10 3 Use of the lance To kill weeds...

Page 18: ...ses usually grasses immediately lighten in colour and flatten to the ground This can be difficult to observe when using hot foam Moss will go bright green In all cases a distinctive smell similar to c...

Page 19: ...ine OFF The whole machine turns off Close the valve to the main water tank You can also shut the machine down by turning the engine off directly without waiting for the boiler to cool down 12 Basic fa...

Page 20: ...th engine on but no or low flow from lance 3 1 Trigger off Press trigger 3 2 Main water valve shut Open valve 3 3 No water in tank Re fill tank 3 4 Leak Ensure all fittings are tight 3 5 Air in water...

Page 21: ...other and positioned over the nozzle tip Replace if necessary SYMPTOM CAUSE REMEDY 5 Green tower light does not come or stay on indicating that the boiler is not reaching temperature 5 1 Boiler not st...

Page 22: ...mstream Plus Change restrictor 0 4mm 0 016 in 8 2 Restrictor has come loose Check O rings on restrictor and push back in SYMPTOM CAUSE REMEDY 9 Flow out of lance too hot steam and or high thermostat r...

Page 23: ...tachometer on the front panel when the engine is off A high level maintenance schedule is detailed on the next pages but for more information ask your distributor about planned maintenance Figure 8 Cl...

Page 24: ...arly 1000h Yearly 1500h 2 Yearly 5000h 3 Yearly Honda GX390 Engine oil Check level Change Air filter Check Clean Fuel line Check Sediment cup Check Clean Charge voltage Check Alternator water pump bel...

Page 25: ...soot Fuel pump filter Electrical connections Water pump Water filter Check Oil level condition Smooth pump operation Pressure hoses and fittings Oil Water leaks 1St oil change Replace Oil change Valve...

Page 26: ...e chassis CARE SHOULD BE TAKEN WHEN LIFTING THE L12 ONLY USE LIFTING MACHINERY AND STRAPS CHAINS CAPABLE OF LIFTING MORE THAN 400 KG 882 LBS 14 1 On vehicle set up It is recommended that the L12 has i...

Page 27: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 15 Schematics Figure 10 L12 P ID...

Page 28: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 28 Figure 11 Wiring diagram rev 1 2...

Page 29: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 29 Figure 12 Electric diagram rev 1 2...

Page 30: ...ould have been apparent to you if earlier d Subject to section 3 below WTL will have no liability if you do not comply with the above e WTL s options in cases where it is liable include repairing or r...

Page 31: ...or alteration in factory foam additive dosage settings Please note that it is not to be inferred or implied from the fact that WTL may supply you with any technical means of altering the settings for...

Page 32: ...on of conformity is available upon request Engine emissions are EURO and USA EPA CARB certified Sound Pressure Level 75 dB A Guaranteed Sound Power Level 87dB A Measurement Uncertainty K 0 4 dB A Weed...