SYMPTOM

 

 

 

CAUSE

 

REMEDY

 

  

Boiler 
switched on 
with engine 
on, but boiler 
does not start 

4.1  No flow, see 3 

See 3 

4.2  Faulty flow switch 

Check by removing and 
checking not blocked. Then 
turn upside down and 
check resistance. Replace 
if necessary. 

4.3 

Faulty pressure 
switch 

Replace pressure switch. 

4.4 

No back pressure 
from lance 

Check lance is fitted and 
with correct and not worn-
out nozzles. 

Check that the pressure is 
at least 5 bar. 

Check that there are no 
leaks 

4.5 

Loose contacts on 
boiler diesel 
pump 

Ensure tightly connected. 

4.6 

Temperature 
limiter switch 
(snap switch) has 
been triggered 

Reset or replace and then 
on restart ensure there is 
full (12lpm) flow through 
the boiler. If not, see 3  

4.7 

Valve in diesel 
pump stuck 
(open or closed) 

Open solenoid valve on 
diesel pump to confirm and 
replace the coil for the 
valves 

   

4.8 

Boiler electrodes 
misaligned 

Open top of boiler to 
expose electrodes and 
ensure no more than 5mm 
from each other and 
positioned over the nozzle 
tip. Replace if necessary. 

     

  

SYMPTOM

 

 

 

CAUSE

 

REMEDY

 

Green tower 
light does not 
come (or stay) 
on, indicating 
that the boiler 
is not reaching 
temperature 

5.1 

Boiler not 
starting, see 4 

See 4 

5.2 

Air in diesel lines 
(reducing fuel 
flow rate into 
pump) 

Ensure all hoses and clips 
are tightly fitted.  

If necessary, disconnect 
and force air out of lines 
before reconnecting. 

5.3  Low diesel 

pressure 

Set the diesel pressure to 
14 bar/203 PSI 

5.4 

Coil in boiler is 
covered in thick 
layer of soot 

Drop a soot-breaker into 
the boiler to clean the coil. 
Then, measure the 
emissions to help ensure 
air and diesel set correctly. 

5.5  Blocked diesel 

nozzle 

Replace diesel nozzle in 
boiler 

5.6 

Thermostat 
setting is 
incorrect, so light 
does not 
illuminate 

Reset 

by holding on ‘P’ 

button for 1 second until 

‘SP1’ appears.

 Then adjust 

up and down. Press ‘P’ 
again to get to ‘SP2’, then 

again to go leave menu. 
SP1 should be 107. SP2 
should be 85. 

5.7 

Accelerator arm 
on engine has 
been moved, 
increasing RPM & 
flow 

Adjust arm and test. 
Options are: Engine RPM 
using tachometer (2000), 
flow rate (12 lpm/3.1 
gpm), or alternator voltage 
(14V). Tighten screw. 

5.8 

Valve stuck in 
diesel pump, see 
4.8 

See 4.8 

 

 

Summary of Contents for Foamstream L12

Page 1: ...EPA Est No 94946 GBR 1 USER MANUAL For L12 019 and above ENGLISH EU USA 15 01 2020 ISSUE 4...

Page 2: ...L12 User manual English EU USA 15 01 2020 ISSUE 4...

Page 3: ..._________________ 15 8 2 BOILER SWITCH __________________________________________ 15 8 3 THERMOSTAT ___________________________________________ 15 8 4 TACHOMETER ______________________________________...

Page 4: ...en if a door or window is open ONLY USE IN A WELL VENTILATED AREA Do not use the L12 in potentially explosive atmospheres 1 3 Electric Shock Hazards WARNING Do not operate the L12 s electrical compone...

Page 5: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 5...

Page 6: ...ggested as best practice IT IS THE RESPONSIBILITY OF THE OPERATOR TO WEAR APPROPRIATE PPE Never operate the machine without checking that there are adequate supplies of clean petrol gasoline clean die...

Page 7: ...ees centigrade the indicator light goes green indicating that it is hot enough for weeding The water flows from the boiler 12 l m 12 bar 3 1 gpm 174 PSI and a venturi mixer opens to allow Foamstream c...

Page 8: ...03 with light WIDTH mm ft 1040 3 42 DEPTH mm ft 980 3 22 or 1950 6 40 with tank WEIGHT kg lbs 360 794 EMPTY 425 937 FULL WATER 780 LITRES 206 GAL DIESEL 32 LITRES 8 45 GAL PETROL GASOLINE 6 1 LITRES...

Page 9: ...ion main switch Cold and Hot boiler on 2 Engine Honda GX390 with speed fixed 3 Water tank 780 litres 206 gal as standard Not represented 4 Lance Not represented 5 Feet forklift slots Forklift can also...

Page 10: ...m and can be used to kill larger weeds Foam cover and hence heat retention on weeds is easier to achieve on prostrate plants that are near the ground Tall plants should be trodden down either by foot...

Page 11: ...ecies and their size 5 3 Caution poisonous weeds Some poisonous weeds such as common ragweed Senecio jacobaea may still be attractive to animals after treatment with Foamstream When treating any area...

Page 12: ...y a blanket of foam The density of the plants and foliage is a very important aspect for the operator to be aware of as this also impacts on the speed of operation It should be noted As the height and...

Page 13: ...return hose and water level sensor are connected Pipe hose routes are clear of sharp edges and hot surfaces There are no signs of leaks from any pipe or connection Petrol gasoline tank is full of cle...

Page 14: ...ill come out Turn the boiler switch to ON position 3 on Figure 7 The switch will illuminate green and the boiler will heat up whenever the trigger is pressed The boiler is only active when the trigger...

Page 15: ...nce keep the trigger pressed and wait for up to 1 minute 8 3 THERMOSTAT The thermostat indicates the water temperature at the outlet of the boiler it can be switched from Celsius to Fahrenheit 8 4 TAC...

Page 16: ...mpletely In the above conditions whereby the machine has run low on input fluids the user simply has to re fill the required fluids and then can restart the machine as usual The below conditions indic...

Page 17: ...ver the vegetation the required volume of hot water and foam may not have penetrated or been applied correctly Total vegetation control will not have been achieved 10 3 Use of the lance To kill weeds...

Page 18: ...ses usually grasses immediately lighten in colour and flatten to the ground This can be difficult to observe when using hot foam Moss will go bright green In all cases a distinctive smell similar to c...

Page 19: ...ine OFF The whole machine turns off Close the valve to the main water tank You can also shut the machine down by turning the engine off directly without waiting for the boiler to cool down 12 Basic fa...

Page 20: ...th engine on but no or low flow from lance 3 1 Trigger off Press trigger 3 2 Main water valve shut Open valve 3 3 No water in tank Re fill tank 3 4 Leak Ensure all fittings are tight 3 5 Air in water...

Page 21: ...other and positioned over the nozzle tip Replace if necessary SYMPTOM CAUSE REMEDY 5 Green tower light does not come or stay on indicating that the boiler is not reaching temperature 5 1 Boiler not st...

Page 22: ...mstream Plus Change restrictor 0 4mm 0 016 in 8 2 Restrictor has come loose Check O rings on restrictor and push back in SYMPTOM CAUSE REMEDY 9 Flow out of lance too hot steam and or high thermostat r...

Page 23: ...tachometer on the front panel when the engine is off A high level maintenance schedule is detailed on the next pages but for more information ask your distributor about planned maintenance Figure 8 Cl...

Page 24: ...arly 1000h Yearly 1500h 2 Yearly 5000h 3 Yearly Honda GX390 Engine oil Check level Change Air filter Check Clean Fuel line Check Sediment cup Check Clean Charge voltage Check Alternator water pump bel...

Page 25: ...soot Fuel pump filter Electrical connections Water pump Water filter Check Oil level condition Smooth pump operation Pressure hoses and fittings Oil Water leaks 1St oil change Replace Oil change Valve...

Page 26: ...e chassis CARE SHOULD BE TAKEN WHEN LIFTING THE L12 ONLY USE LIFTING MACHINERY AND STRAPS CHAINS CAPABLE OF LIFTING MORE THAN 400 KG 882 LBS 14 1 On vehicle set up It is recommended that the L12 has i...

Page 27: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 15 Schematics Figure 10 L12 P ID...

Page 28: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 28 Figure 11 Wiring diagram rev 1 2...

Page 29: ...L12 User manual English EU USA 15 01 2020 ISSUE 4 29 Figure 12 Electric diagram rev 1 2...

Page 30: ...ould have been apparent to you if earlier d Subject to section 3 below WTL will have no liability if you do not comply with the above e WTL s options in cases where it is liable include repairing or r...

Page 31: ...or alteration in factory foam additive dosage settings Please note that it is not to be inferred or implied from the fact that WTL may supply you with any technical means of altering the settings for...

Page 32: ...on of conformity is available upon request Engine emissions are EURO and USA EPA CARB certified Sound Pressure Level 75 dB A Guaranteed Sound Power Level 87dB A Measurement Uncertainty K 0 4 dB A Weed...

Reviews: