Wecon LX3V-2ADV-BD User Manual Download Page 3

                                                                                                                                       

LX3V-2ADV-BD

 

2                                                       

                                                                           

  WECON Technology Co., Ltd. 

M8113 

The flag of switching Input mode in CH2 
OFF:    Voltage input mode (-10V~10V, -2000~2000) 

D8112 

The digital value of channel 1; (-10V~10V, -2000~2000) 

D8113 

The digital value of channel 2; (-10V~10V, -2000~2000) 

Expansion port 2 (from the PLC light near)

 

Address 

Description   

M8116 

The flag of switching Input mode in CH1 

OFF: Voltage input mode (-10V~10V, -2000~2000) 

ON: 
Disabled 

M8117 

The flag of switching Input mode in CH2 
OFF: Voltage input mode (-10V~10V, -2000~2000) 

D8116 

The digital value of channel 1; (-10V~10V, -2000~2000) 

D8117 

The digital value of channel 2; (-10V~10V, -2000~2000) 

 

3.

 

Dimension 

                                      Table 3-1 

 

 

LED lights indicating: 

1)

 

LED1: ON when power ON. 

2)

 

LED2: flashes when communications. 

3)

 

LED3  (AD  1):  On  indicates  enable,  OFF  indicates  disable,  flicker  indicates  exceeding  the 
measurement range. 

4)

 

LED4  (AD  2):  On  indicates  enable,  OFF  indicates  disable,  flicker  indicates  exceeding  the 
measurement range. 

 

If the BD module is plugged into the PLC which uses old firmware version, when PLC power on, all 

LEDs will be flashing. 

 

IN-2ADV input voltage range: -10~10V 

Vi1+ 

Anode of the channel 1 voltage input 

Vi1- 

Cathode of the channel 1 voltage input 

• 

No connection 

Vi2+ 

Anode of the channel 2 voltage input 

Vi2- 

Cathode of the channel 2 voltage input 

Reviews: