![Weco UNIVERSAL 5K3HV Installation And User Manual Download Page 53](http://html1.mh-extra.com/html/weco/universal-5k3hv/universal-5k3hv_installation-and-user-manual_949486053.webp)
WECO 5K3 LV/HV
53
3.1
Product Introduction
The WeCo Module 5K3 LV/HV Battery Modules can be used as an on-grid or off-grid energy storage system. It is not
recommended to use this product for any purpose other than the intended purpose as described in this document.
Use of this product other than as described in this document will nullify the Product Warranty. The substitution of any
components of this battery will nullify the Product Warranty.
The use of any components contained within or connected to this battery other than the products sold as part of this product
or recommended by the manufacturer will nullify the Product Warranty.
ATTENTION:
Do not exceed the number of 8 modules in each tower.
ATTENTION:
The maximum number of Battery Modules that can be connected in series is 16.
ATTENTI
HV Box is a compulsory protection and communication device that must be installed for any High Voltage
Configuration.
ATTENTION:
Attempting to operate a system of Battery Modules with less than four modules in series or more than 16 modules in series
will nullify the Product Warranty.
Battery Module Weight 126.3 lb / 57.3 kg
ATTENTION:
EXAMPLE:
A cluster of 12 Battery Modules weigh 1515.6 lb /687.6 kg The support structure/floor must be properly inspected by a civil
engineer before starting the installation of the modules.
3.1.1
Identifying the Individual Module
Dimensions
mm
576x461x156
Cell type
mm
LiFePO4
Weight
lb (kg)
126.3 lb
(57.3 kg)
BMS Charge Temp
°F (°C)
+19.4°F to +131°F*
(-7°C to +55°C*)
Case Material
Type
Steel
BMS Discharge Temp
°F (°C)
+131°F to -4°F*
(+55°C to -20°C*)
Modules in
series
Max No.
16
Suggested Storage Temp
°F (°C)
+77°F (+25°C)
(shelf life 1 year)
Stackable
Type
Yes
Storage Temp/Time
outside the suggested
storage temperature
°F (°C)
-13°F to +131°F /
4 months
(-25° +5°C to +30°C+55°C /
4 months)
Digital Output
No.
2+2
Self-Discharge @ STC
77°F (25°C)
%
1% per month
Cell Distribution
P/S
16S
Self-Discharge outside the
STC
%
< 3% per month
Summary of Contents for UNIVERSAL 5K3HV