WELD THE WORLD
Cod. 006.0001.1820
25/05/2018 V.2.6
Cruiser 322/402/502AC/DC
Power Pulse 322/402/502AC/DC
19
ENGLISH
MESSAGE
MEANING
EVENT
CHECKS
E. 69
Software compatibility error
Indicates that the welding power
source has a software version that
is not compatible with the remote
device connected to it (remote
controller, wire feed unit).
All functions disabled.
Exceptions:
• Cooling fan.
•
Update the remote device soft
-
ware.
•
Contact support
E. 04
Alarm, no-load voltage failure
All functions disabled.
Exceptions
:
• Cooling fan
•
Check to ensure the welding
torch is not resting on the work
-
piece connected to ground.
•
Check that when the power
source is switched on there
is no short circuit between the
sockets (voltage must be great
-
er than/equivalent to Ur).
If the problem persists:
•
Qualified technical personnel
are required for repair/mainte
-
nance jobs.
E. 05
Torch button alarm
Indicates that when the power
source was powered up a short
circuit was detected on the torch
trigger input.
When the unit has cooled, the
welding power source will reset
automatically.
All functions disabled.
Exceptions
:
• Cooling fan.
•
Make sure the torch trigger is
not pressed, jammed, or short
circuiting.
•
Make sure the torch and torch
connector are intact.
CAn Err.
No communication alarm
Indicates the presence of prob-
lems in data communication be
-
tween the power source and wire
feeder. When the unit has cooled,
the welding power source will re
-
set automatically.
Exit the alarm state by performing
one of the following actions:
Switch the power source off.
All functions disabled.
Exceptions
:
• cooling fan.
•
cooler (if switched on).
• Check that the connecting cable
between power source and wire
feeder is intact and make sure
the connectors are securely
tightened.
If the problem persists:
•
qualified technical personnel
are required for repair/mainte
-
nance jobs.