30
7.
ENTER
%
Press <ENTER> key to end data entry.
The right form is displayed.
8.
1
2
3
4
5
6
7
8
9
0
%
Enter decentration data on the key pad.The data quantity and
type depends on the selected decentration menu.(see 5.5).
•
Press <ENTER> key to end data entry.
%
Decentration point and blank diameter are calculated
automatically.
•
Place the lens in the lens support.
Note:
The lens illmination is only activated when the lens
is
in the parallax free zone.
9.
C
%
Use the <C> key to correct the decentration values
Note:
When the <ENTER> key is pressed longer the
change will be effective immediately.
10.
BLOCK
%
Use the <BLOCK> key to position the table in the parallax free
zone.
The lens illumination is activated.
%
Place the reading segment symmetrically and with correct axis on
the lay-out grid.
%
Check the blank diameter.
•
Place the Vario Block with block pad in the block adapter.
•
Move the blocking device over the lens.
The lens is blocked automatically.
11.
R/L
%
Press <R/L> to select left lens.
the left form is displayed and the decentration data of the right
lens is applied.
•
You can overwrite the data or use the <ENTER> key to jump
the fields.
•
proceed as under point 8.