![Weco cad III Operation Manual Download Page 28](http://html1.mh-extra.com/html/weco/cad-iii/cad-iii_operation-manual_949489028.webp)
28
10.
BLOCK
%
Use the <BLOCK> key to position the table in the parallax free
zone
The lens illumination will turn on.
%
Single vision lens
Super impose the optical center on the
decentration point
Pogressives:
Super impose the decentration cross on the
decentration point
%
Check the blank diameter.
•
Place the Vario Block with block pad in the block adapter.
•
Position the blocking device over the lens.
The lens is blocked automatically
11.
R/L
%
Press <R/L> key for left lens.
The left form is displayed, the decentration values of the right
lens are applied.
•
Overwrite the data or pass the fields by using <ENTER>
key.
•
Commence as described under point 8.