Page
14
of
16
The manifold block is secured in position using the two socket cap screws on the anvil lever side
of the cutter
The manifold block is fitted with intensifier and hoses, if the intensifier is removed it is
important that it is replaced in exactly the same position. The hose connected to the ‘BLADE
DOWN’ port must be connected to the Intensifier port marked ‘IN’ and the hose connected to
the ‘BLADE UP’ to the Intensifier ‘R’ port.
Below is shown the cutter with a side plate removed to show the hose arrangement
The two hoses connected to the far ports on the underside of the auxiliary cylinders, are both
connected to the underside of the ‘ANVIL OPEN’ port, the two other hoses connected to the
front of the auxiliary cylinders connect to the underside of the ‘ANVIL CLOSED’ port.