![WEBTEC FlowHUB Series User Manual Download Page 5](http://html1.mh-extra.com/html/webtec/flowhub-series/flowhub-series_user-manual_949422005.webp)
English
Functional Specification
l
Flow range
: see model configuration
l
Pressure range:
see model configuration
l
Ambient operating temperature:
- 5 to 40 °C
l
Fluid type:
hydraulic oil
l
Fluid temperature:
5 to 90 °C
l
Accuracy:
± 3% of full scale at 21 cSt (higher
accuracy on request)
l
Repeatability:
better than ± 1%
l
Response time:
150 ms (
Switch and Transmitter
),
50 ms (
Ultimate
)
l
Protection:
designed to meet IP64
Electrical specification
l
Supply voltage:
15 to 30 VDC class 2 supply only
l
Typical current:
35 mA
l
Maximum current excluding switch current:
60 mA
l
Switch current:
500 mA per switch max.
l
Switch Voltage:
supply voltage - 0.5 V
l
Connector type:
M12 - 5 pin male
l
Voltage output:
minimum load = 10K Ohms
l
Current output:
maximum load = (supply voltage x
46) - 200 ohms
l
Recommended cable
: screened cable, 5 x 0.25(2)
(24AWG)
1
- + supply
2
- switch 1 *
3
- GND
4
- switch 2 *
5
- Analogue out: either 0 - 5V or
4 - 20 mA *
* These are options according to model and
may not be operational.
1
2
3
4
5
Pin Connection Details