![WebGate HS1620F-D User Manual Download Page 21](http://html1.mh-extra.com/html/webgate/hs1620f-d/hs1620f-d_user-manual_949232021.webp)
20
1)
Turn off DVR.
2)
Turn off eSATA then connect it to DVR.
3)
Turn on eSATA.
4)
Turn on DVR.
Connecting input/out terminals
Wire end handling
See below for wire end handling used in terminal block. Please work on single line and multiple line as they
have different thicknesses.
Wire insertion/removal
As shown in the picture, push the lever to insert or remove a
wire.
Connecting the sensor
specification
below requirements need to be met in order to connect the sensor
Specifications
Input Channel #
16EA Transistor input
Input Type
N.C, N.O support
Supported sensor
Dry contact sensor
Connection method
Connect the trimmed wire to terminal block
Performance
Available input
pulse range
Minimum 500ms
Output current
Standard DC 12mA
* Adopted differently based on product specification
Connecting sensor input terminal
Please see the picture for sensor input. The below picture is an example of connecting Dry Contact sensor type.
Please refer to “Wire Handling” for more information.
- Multiple lines : Peel off the recommended length(8~10mm) and lead-coat it. Use AWG 22 ~ 26.
- Single line : Peel off the recommended length(8~10mm) and use AWG 20 ~ 26.
Summary of Contents for HS1620F-D
Page 1: ...0...
Page 33: ...32 SPOT Run Tool SPOT in live to select channel to be on SPOT screen or Auto sequence...
Page 82: ...81 Product specification HS1620F PD...
Page 83: ...82 HSC821F PD...
Page 84: ...83 HS1620F D...
Page 85: ...84 HSC1621F D...
Page 86: ...85 HSC821F D...
Page 87: ...86 Product Dimension HS1620F PD...
Page 88: ...87 HSC821F PD...
Page 89: ...88 HS1620F D...
Page 90: ...89 HSC1621F D...
Page 91: ...90 HSC821F D...