15
DIP Switch Setup
Installation -
2
2. Communication Baud Rate Setup
Select the appropriate baud rate with DIP switch combination.
1
2
3
4
5
ON
8J
2
1
3
4
5
6
7
8
2400 BPS -
Factory Default
ON
8J
2
1
3
4
5
6
7
8
4800 BPS
ON
8J
2
1
3
4
5
6
7
8
9600 BPS
ON
8J
2
1
3
4
5
6
7
8
19200 BPS
38400 BPS
ON
8J
2
1
3
4
5
6
7
8
3. RS-485 Termination Resistor
- Pin 8 is used for on/off of RS-485 termination.
- Normally, it must be OFF.
- When you have trouble with long daisy chain style
connections, turn ON this termination switch on the last
camera.
ON
8J
2
1
3
4
5
6
7
8
4. Camera ID Setup
The ID number of the camera is set using binary numbers.
See the example below.
Interface Board
Pin
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
128
ID Value
ex) ID=5
ex) ID=10
on
off
off
on
on
off
off
on
off
off
off
off
off
off
off
off
- If you want to control a certain camera, you must match the
camera ID with ‘CAM ID’ setting of DVR or keyboard controller.
- The range of Camera ID is 0~255.
- All cameras have a factory default Camera ID of 1.
- Camera ID will be effective without having to reboot the
camera.