4.4
Equipment connections
SINGLE coupling
Connecting:
Remove the protective cap from the coupling male and the coupling female (Fig. 1).
Conflate SINGLE coupling male and female in the bayonet catch (Fig. 2). Hold coupling female
on the black slew ring and turn clockwise until the coupling snaps in (Fig. 3). Put protective caps
together (Fig. 4). You don’t have to switch the power unit to position 0 to connect or disconnect
the coupling!
Disconnecting:
Remove the protective caps. Hold coupling female on the black slew ring and turn
anticlockwise direction. Turn the black slew ring until you can release the coupling easily. Put
protective caps to coupling male and the coupling female.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
NOTE !
When using the SINGLE coupling, pressure relief connectors are no longer
required.