When mounting the new tamping foot the nuts (1) must be
tightened with a torque of 35 Nm.
Change the oil in the tamping system
Unscrew the screw plug (1) from the fill opening.
Tilt the tamper slightly and let the old oil drain into a suitable
collection container. Set down the tamper and fill oil in
as specified.
Clean the screw plug and screw it into the fill opening.
Select a collection vessel that is large enough to prevent
oil from spilling on the ground. Dispose of waste oil in an
environmentally friendly manner (regulation on waste oils).
Change the tamping foot
Unscrew the 4 nuts (1).
Lift the tamping foot (2) off of the tamper and attach a new
tamping foot.
Mount the fastening nuts of the tamping foot using the
plate springs as shown in the adjacent illustration.
Mounting arrangement
of the plate springs
Dispose of oils, greases, cloths soaked in oil, and
replace parts with oil on them in an environmentally
friendly manner.