Troubleshooting
Operating fluids and fill levels
Fault
Possible cause
Remedy
Tamper does not start
Operating error
Execute the start process
as prescribed
Battery switched off
Discharge the battery
Charge the battery
as described
Plug connection battery / device
not or not properly established
Check the plug connection
Engine runs, but stops
after a short time
Discharge the battery
Charge the battery
as described
Engine runs at full rpm,
tamper does not tamp
or tamps inadequately;
unclean compaction pattern
Centrifugal clutch is defective Repair
Tamping foot is worn
Change the tamping foot
Tamper has no power
Excess grease in the tamping
system
Open / clean the tamping
system
Assembly
Lubricant
SRE
Quality
300
Tamper lower part
Shell Gadus S2 V 220AD 2 or
comparable KP2K-20 grease
As necessary
Lubricating points
Shell Gadus S2 V 220AD 2 or
comparable KP2K-20 grease
Every 50 h.