Designated Control Panels
The chiller unit is operated and controlled by the
Chiller Control
digital control panel.
Directly
connected air-handlers for one cabin are also operated by this control panel.
Other cabins with
indirectly
connected air-handlers are controlled by separate
Air Control
digital
control panels.
The system must be started with the Chiller Control prior to normal functionality of the air-
handlers in other cabins.
Chiller Control
•
Start and stop of the chiller unit
•
Programming and setup of the chiller unit
•
Setup of directly connected air-handlers
•
Selection of operation mode (Automatic, Cooling, Heating)
Air Control
•
Start and stop of indirectly connected air-handlers
•
Temperature and blower setting for indirectly connected air-handlers
The operation mode can not be selected with the Air Control!
„Chiller Control“ for chiller and directly connected air-handlers
The digital control panel is always factory pre-programmed and the secondary commands are
code-protected.
•
If your chilled water system has a heating option, the cabins can be heated until the sea-water
temperature drops below 10°C (50°C).
The function
„Automatic with Reverse Cycle” (f3)
is pre-set.
•
If an external water heater is integrated in your chilled water system, you can heat independently
from the sea-water temperature (See chapter “External Heater” in the operation manual).
The function
„Automatic with External Heater” (f4)
is pre-set.
Heat Cycle
Mode
Manual Blower
Operation
Cool Cycle
Mode
Read-Out
(0)
Higher
Values
(Sun)
Lower
Values
(Snow flake)
Function/Blower Speed
(F)
On/Off