„Air Control” for indirectly connected air handlers
The digital control panel is always factory pre-programmed and the secondary commands are
code-protected.
Starting
Press once the
button.
On
is displayed and after appr. 20 sec. the
current room temperature, e.g.
28.5
(°C) (83°F) is shown.
Setting the
Temperature
With the buttons and between 15°C (59°F) and 29°C (84°F) while the
room-temperature is displayed.
e.g. room temperature 25° C (77°F)
Set temperature = 20°C (68°F), Cool mode starts.
Set temperature = 29°C (84°F), Heat mode starts.
Attention: Only the mode that is preselected by the Chiller Control
can be started.
Setting Blower
Speed
Press the button
until
b
is shown to the left and the selected value to the
right, e.g.
b 5
(
Blower speed 5)
•
Value Range (Blower speeds):
1-2-3-4-5
and
A
•
Factory Setting:
A
(Automatic Blower Speed)
Program with the buttons and . Confirm by pressing the
button.
Secure your setting by pressing the
button. The display shows
memo
and then the room-temperature.
→
In the automatic blower speed mode (
b A)
the blower start and
operation depends on the temperature. If there is no need for blower
operation, the display shows
ba11
. It can take some time before the blower
starts.
→
The manual blower speed mode (
1 to 5
) is indicated by the LED
„Manual blower operation“.
Displaying the
Evaporator
Temperature
Press the
button until
E
is shown to the left and a numerical value to the
right, e.g.
E10.5
.
Heat Cycle
Mode
Manual Blower
Operation
Cool Cycle
Mode
Read-Out
(0)
Higher
Values
(Sun)
Lower
Values
(Snow flake)
Function/Blower Speed
(F)
On/Off