LVD 

LVD “Low Voltage Disconnect” allows the user to 
set the battery voltage level at which the Webasto 
SmarTemp Control 2.0 will shut down the heater. 

 

If battery voltage is equal to or less than the 
threshold se0.1v, the heater will not start. 
I.e. if an 11.5v threshold is selected the heater 

cannot be started until B+ has reached 11.7v. 
12 volt - Range between 
11v – 12.5v 24 volt - 
Range between 21v – 
25.5v 

 
 
 
 

 
 
 

11.4v 
24.2v 

Password 

A password can be set to prevent access to the 
advanced “Options” menu. Enter a 4 digit code 
passcode to begin securing the “Options” menu. 

Note: 

This is typically used in fleet vehicle 

applications. 

OFF 

PM 
Reminder 

If  the  heater  has  not  run  30  days,  the  preventive 
maintenance  (PM)  reminder will alert  the operator 
with a message to run the heater for 20 minutes. 
The indicator lights will flash red as a visual reminder. 
The  operator  will  have  the  ability  to  Start  the  20 
minute maintenance cycle or delay it via a “Snooze” 
option.  When  Snooze  is  selected  the  PM  reminder 
will postpone until 12:00PM the following day. 

ON 

Time & Date 

Set time and date using the rotary knob and 
selection button. 12 (AM / PM) or 24 hour available. 
The Webasto button can be used to go back to the 
previous field if additional changes are needed. 

12 hour 

Offset 

Depending on the installation location, the 
temperature reading may vary slightly. The Offset 
feature allows a temperature adjustment of +/- 
9°F (+/- 5°C). Adjust this as necessary to obtain 
the most accurate ambient temperature reading. 

0° 

Default 

Default allows the user to perform a factory reset of 

the control settings. 

Note: 

Heater information will NOT be affected. 

N/A 

Use the following link to obtain version specific 
controller operation instructions. 

http://www.techwebasto.com/documentation/heater/re
creational.html

 

Summary of Contents for Air Top Series

Page 1: ...er is in use the product surface connected hoses ducting and air outlet s may become hot to the touch Contact with skin may cause burns 2 Webasto heaters must be switched OFF when re fueling at fillin...

Page 2: ...ir heaters is exposed to very high thermal stress and must be replaced by a genuine Webasto spare part ten years after it is used for the first time If exhaust lines pass through areas used by personn...

Page 3: ...tems at the heater 23 Do not place any items of clothing textiles or similar materials over the heater or in front of the hot air inlet and the hot air outlet 24 The heater must not be cleaned with a...

Page 4: ...cts on or against the heater before you turn it on Ventilation Option A separate switch optional allows the user to choose between heating and ventilation mode In ventilation mode the fan speed depend...

Page 5: ...the Selection button Select edit from the sub menu 3 Adjust and select day for Friday 4 Adjust and select time for 6 30AM 5 Adjust and select runtime for 60 minutes 6 Settings are saved each time the...

Page 6: ...ure Output Heater Runtime Example Air Heater Using the rotary dial and the selection button follow these steps to set your cab temperature to 70 F with a runtime of 1 hour 3 Press the Select button Us...

Page 7: ...are saved each time the selection button is pressed If the timer function will be used regularly for next day startups the ANY setting can be used in place of the day of the week With this set the ti...

Page 8: ...he Brake Input pin of the SmarTemp 3 0 connector NOTE This feature is only used in original equipment applications Enabled Heaters 3 0 Allows you to name the heater s connected to the SmarTemp through...

Page 9: ...es The indicator lights will flash red as a visual reminder The operator will have the ability to Start the 20 minute maintenance cycle or delay it via a Snooze option When Snooze is selected the PM r...

Page 10: ...during operation Heater unit overheats andindica tor flashes Switch heater unit off for at least 2 seconds and then on again Switch heater unit off for at least 2 seconds and then on again Make sure...

Page 11: ...t or short circuit F 06 Temperature sensor interrupt or temperature sensor short circuit F 07 Metering pump interrupt or metering pump short circuit F08 Fan motor interrupt or fan motor short circuit...

Page 12: ...The fuel supply is stopped if the heater overheats The heater continues to run in the same way as if it is switched off manually After the heater stops the control unit may set in fault lock out mode...

Page 13: ...the original warranty period whichever is longer The intent of the Webasto warranty is to protect the original end user of the heater from defects and provide free repair and replacement of defective...

Page 14: ...Webasto Thermo Comfort N A Inc 15083 North Road Fenton MI 48430 Technical Assistance Hotline USA 800 860 7866 Canada 800 667 8900 Org 3 2017 Rev 05 2021 P N 5012526D www webasto us www techwebasto com...

Reviews: