9
LVD
LVD “Low Voltage Disconnect” allows the user to
set the battery voltage level at which the Webasto
SmarTemp Control 2.0 will shut down the heater.
If battery voltage is equal to or less than the
threshold se0.1v, the heater will not start.
I.e. if an 11.5v threshold is selected the heater
cannot be started until B+ has reached 11.7v.
12 volt - Range between
11v – 12.5v 24 volt -
Range between 21v –
25.5v
11.4v
24.2v
Password
A password can be set to prevent access to the
advanced “Options” menu. Enter a 4 digit code
passcode to begin securing the “Options” menu.
Note:
This is typically used in fleet vehicle
applications.
OFF
PM
Reminder
If the heater has not run 30 days, the preventive
maintenance (PM) reminder will alert the operator
with a message to run the heater for 20 minutes.
The indicator lights will flash red as a visual reminder.
The operator will have the ability to Start the 20
minute maintenance cycle or delay it via a “Snooze”
option. When Snooze is selected the PM reminder
will postpone until 12:00PM the following day.
ON
Time & Date
Set time and date using the rotary knob and
selection button. 12 (AM / PM) or 24 hour available.
The Webasto button can be used to go back to the
previous field if additional changes are needed.
12 hour
Offset
Depending on the installation location, the
temperature reading may vary slightly. The Offset
feature allows a temperature adjustment of +/-
9°F (+/- 5°C). Adjust this as necessary to obtain
the most accurate ambient temperature reading.
0°
Default
Default allows the user to perform a factory reset of
the control settings.
Note:
Heater information will NOT be affected.
N/A
Use the following link to obtain version specific
controller operation instructions.
http://www.techwebasto.com/documentation/heater/re
creational.html