10.0 Advanced Menu
and ending on the first Sunday in November. If you would like to
adjust these settings, you may do so in this menu.
10.11 NUM START
This SmartLine® feature allows you to select the number of
Watering Program Start Times that you want to appear at
Program Start Times on the dial. The default number of start
times shown is 3. To select 4 to 8 start times, go to Advanced
Functions, NUM STRT. Press Next to view the default of 3 start
times. Scroll the UP/DOWN buttons to select 4 to 8 start times
to be visible on the dial. Return the dial to Run.
10.12 MV2 ZONE
A second master valve circuit can be enabled in this menu by
designating a zone valve to be MV2
10.13 ZN/ZN DLY
This function allows user to set delay times between zone starts
for use in systems with slow closing valves or pump systems that
are operating near maximum flow or have slow well recovery.
Use UP and DOWN buttons to change value. Adjustable in one-
minute increments from 0 (the SmartLine® controller default
setting) to 30 minutes; adjustable in 10 minute increments from
30 minutes to 3 hours.
10.14 MV/ZN DLY
(Master Valve Advance Open and Delayed Close):
This function allows the user to set a delay time between the
opening of the master valve and the opening of the first zone
valve as well as a delay between the closing of the last zone
valve and the closing of the master valve.
Use the NEXT button to enter menu. Select setting for the ON
Delay or OFF Delay by pressing NEXT. Use UP and DOWN
buttons to select delay time. Use the UP and DOWN buttons
to set ON Delay time from 0 seconds to 1 minute in 1 second
increments. OFF Delay can be set from 0 seconds to 3 minutes
in 1 second increments.
10.15 MV/ZONE
This feature is used to indicate which zones will use the master
valve/pump start output. Use NEXT button to set each zone ON
or SYSTEM OFF (SmartLine® controller default is master valve
ON for all zones). Use UP and DOWN buttons to select ON or
OFF. Use NEXT button to select zone.
Caution: If an unused zone is turned on and activates a pump
start relay, the pump may overheat or cause a pipe to burst. To
prevent operating a pump with no flow (dead heading), make
sure all unused zones are set to OFF.
10.16 NC/NO MV
Enter this menu to select between normally open or normally
closed master valves for master valve 1 and master valve 2.