WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
7.4. Configuring the module and modifying the device settings
It is strongly recommended to have identical settings on all devices, which have
to open a connection with each other or are to be used in Beacon mode.
The module’s parameters are stored in flash, but have a local copy in RAM. The flash param-
eters can be modified by the
, read by the
and retain their content
even when resetting the module.
7.4.1. CMD_SET_REQ
This command enables direct manipulation of the parameters in the module’s settings in flash.
The respective parameters are accessed by means of the corresponding settings index, which
can be found in Table
Parameters of 2 or more Bytes have to be transferred with the LSB first unless noted differently
in the corresponding description.
The modified parameters only take effect after a restart of the module. This
may be done by a
if the module does not restart automatically.
The flash memory used to store these settings has a limited count of write
cycles of minimum 10.000. Try to avoid performing periodic
as
each command will use one write cycle.
The validity of the specified parameters is not verified. Incorrect values can
result in device malfunction!
To save the parameters in the flash memory of the module, the particular mem-
ory segment must first be flushed entirely and then restored from RAM. If a
reset occurs during this procedure, the entire memory area may be corrupted
(e.g. due to supply voltage fluctuations).
Recommendation: First, verify the configuration of the module with
and only then apply a
if required to avoid unnecessary flash
cycles.
Format:
Order code 2611011024000
81
Version 1.8 , July 2022