background image

4

Phase Two

Luminaire Installation, Electrical Connection, and

Aiming Procedure

4)  Switch off mains electrical supply.

5)  Check that rating shown on luminaire label conforms 

with mains electrical supply.

6) Remove screws 

M

 from mounting ring 

H

.

7)  Use sealable junction box 

J

 to connect luminaire 

cable 

N

 to mains supply cable 

O

 (for individual  

wiring or branch cable through wiring). Follow the 

sealable junction box termination instruction  

included in the packaging.

8) Remove cover 

A

 and lens/gasket assembly 

B

 by 

loosening screws 

D

9)  Set cables and sealable junction box 

J

 inside  

installation blockout 

L

.

10) Place luminaire housing 

C

 into installation block-

out/mounting ring assembly 

L/H

. Secure luminaire 

with mounting ring 

H

 by tightening screws 

M

.  

Warning:

 When luminaire is placed inside installa-

tion blockout 

L

, ensure there is no stress on seal-

able junction box 

J

 or electric cables (Fig. IV).

11) Switch on mains electrical supply to ignite the  

factory-installed LED.

Rotate and tilt the gimbal optic

12) Insert a standard tool into one of the radial cavities 

of wheel 

W

. Rotate wheel 

W

 in the direction of the 

'OPEN' mark until the gimbal optic can freely rotate 

and tilt

 

(Fig. V).

 

To rotate the gimbal optic

 

(360° rotatable) 

a) Grasp both sides of catching ribs 

E

b) Rotate gimbal optic to the desired orientation 

(while observing the degree on protractor scale 

G

).

 

To tilt the gimbal optic

 

(swivel-tilted 0-20°, 2° steps) 

c) Insert a standard tool into hole 

T.

 

d) Tilt gimbal optic to the desired orientation (while 

observing the degree on protractor scale 

U

).

13) Insert a standard tool into one of the radial cavities 

of wheel 

W

. Rotate wheel 

W

 in the direction of the 

'LOC

.

' mark until the gimbal optic is 

Ƃ

rmly secured

 

(Fig. V).

 

Warning:

 Do not apply more torque than required 

to 

Ƃ

rmly secure the gimbal optic.

14) Ensure that all surfaces are clean and dry. 

Reposition cover 

A

, lens/gasket assembly 

B

 and 

screws 

D

 on luminaire housing 

C

.

15) Leave the LED ignited for approximately 30 minutes 

to allow any moisture to evaporate (do not tighten 

screws 

D

). 

Attention:

 Do not switch off LED before luminaire 

is properly sealed.

16) Tighten  screws 

D

 (in a criss-cross pattern) until all 

screws are properly seated and secured. Repeat 

tightening procedure, again in a criss-cross pattern, 

for another two rounds with a torque of 3 Nm.

Summary of Contents for ETC120-GB LED

Page 1: ...ainst lightning and electrical surges it is essential to cover mains supply and data input lines at the distribution board level by using respective primary Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operat...

Page 2: ...1 IP67 Class I ta 25 C Inground Luminaire ETC120 GB 2Sen L o c N 2Sen L o c N Fig I ...

Page 3: ...odule proceed as follows Fig I a Rotate wheel W using a standard tool in the direction of the open mark until the gimbal module can be pulled out of the luminaire housing b Detach terminal connector Y and remove gimbal module X c Properly package gimbal module X and return to WE EF for factory maintenance Attention During the factory maintenance period ensure both the luminaire cover and lens are ...

Page 4: ...he shown installation methods In landscape areas soil with gravel base Fig II In paved areas concrete with gravel base Fig III Fig III Fig II Phase One Blockout Installation Procedure during earth or masonry work 1 Ensure a suitable recess is provided to accommo date installation blockout mounting ring assembly L H 2 Set installation blockout mounting ring assembly L H in position and ensure that ...

Page 5: ...ial cavities of wheel W Rotate wheel W in the direction of the OPEN mark until the gimbal optic can freely rotate and tilt Fig V To rotate the gimbal optic 360 rotatable a Grasp both sides of catching ribs E b Rotate gimbal optic to the desired orientation while observing the degree on protractor scale G To tilt the gimbal optic swivel tilted 0 20 2 steps c Insert a standard tool into hole T d Til...

Page 6: ...5 ...

Page 7: ...6 Open L o c k G T W E U F Fig V Fig IV ...

Page 8: ...nfo switzerland we ef com WE EF LIGHTING United Kingdom Tel 44 844 880 5346 Fax 44 844 880 5347 info uk we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 info asiapaciƂc we ef com WE EF LIGHTING Australia Tel 61 3 8587 0444 Fax 61 3 8587 0499 info australia we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9132W0218 WE ...