USING THE MLC8B

 

 
The MLC8B is designed to display the levels of multiple audio signals in a surround

 

   

   

 

 

   

 

 

     

 

sound environment (5.1 + 2) and to provide acoustic mixing of these signals with an

 

 

     

   

 

 

   

 

 

 

 

overall global level control. Every effort has been made to make using the MLC8B as

 

 

 

 

 

 

 

 

   

 

 

 

   

intuitive as possible. 
  
All connections to the unit are made on the rear panel and all displays and operating

 

   

 

 

 

 

 

 

 

 

   

 

 

 

controls are located on the front panel. 
 
The MLC8B accepts AES, 110 Ohm, balanced audio signals, analog audio signals or

 

 

 

 

 

 

 

 

 

 

 

   

AES audio signals embedded in a 3G, HD or SD SDI video stream. The operator must

 

 

 

     

 

   

 

 

 

 

 

 

 

switch the input selector to the type of signal being controlled. To select the Group 3

 

 

 

   

 

   

 

 

 

 

 

 

   

and Group 4 signals from the SDI data stream for disembedding, the button labelled

GR

 

   

 

 

 

 

 

   

 

 

 

 

 

3/4 

must be selected.  

 
The push buttons labelled

AES, ANALOG, SDI 1, SDI 2 and GR 3/4

in the cluster of

 

 

 

 

 

 

   

   

 

 

   

 

   

five LED illuminated push buttons on the right­hand side allows the operator to select

 

 

 

 

 

 

 

 

 

 

 

   

 

the input signal source. The LED in the push button will illuminate to show the selection

 

 

 

 

 

   

 

 

 

 

   

 

 

 

that had been made. Please note that a mix of signal types can not be controlled

 

 

 

 

 

 

   

   

 

 

 

 

 

 

simultaneously. 
 
When the sixth button in the cluster, labelled

ST MODE

, is pushed inputs one through

 

 

 

   

 

 

 

 

   

 

 

 

 

six (AES 1, 2 and 3) and (Analog 1, 2, and 3) are disconnected the seventh and eighth

 

     

   

 

     

   

 

 

 

 

 

 

channels (AES4) and (Analog4) are switched to the inputs 1 and 2 controls. This allows

 

 

 

 

 

   

 

   

   

 

 

 

the operator to listen to the

ST L and ST R

on the

L and R

monitor speakers. In the

ST

 

   

   

 

   

 

   

 

 

 

 

 

 

   

 

 

MODE

 the 

C, LFE, LS and RS

 controls are disabled.  

 
Eight bargraph displays on the left­hand side show the level of the incoming signal. The

 

 

   

 

 

 

 

 

   

 

 

 

 

factory setting for the bargraph meters is ­20dBFS = 0. Field calibration of the meter for

 

 

 

 

 

   

     

 

   

 

 

 

other nominal levels is achieved by using DIP switches 3 and 4 on the rear panel.  
 

SW3

SW4

NOMINAL

 

Down

Down

­20dBFS 

Down

Up

­18dBFS 

Up

Down

­16dBFS 

Up

Up

­12dBFS 

 
 
 
The eight rotary level controls labelled

L, R, C, LFE, LS, RS, ST L and ST R

are used

 

 

 

 

 

 

     

 

 

 

   

 

 

 

 

 

to adjust the level of the individual signals being fed to the output of the MLC8B. These

 

 

 

   

 

 

 

 

   

 

   

 

 

 

rotary controls are equipped with concentric array of LED indicators that show the

 

 

 

 

 

 

   

 

 

 

 

 

proportionate value of the signal. Each rotary control incorporates a push­push switch

 

   

 

 

 

 

 

   

 

 

that instantly mutes that signal. When muted the concentric LEDs extinguish except for

 

 

 

 

 

 

 

 

 

 

 

   

Summary of Contents for MLC8B

Page 1: ...MLC8B MULTI CHANNEL LEVEL CONTROL by Ward Beck Systems Rev Oct 01 2014 ...

Page 2: ...ions to the unit are made on the rear panel Please note that the 25 pin DB female connector labelled AUX 1 is used to connect the analog inputs while the 25 pin DB male connector labelled AUX 2 is used to connect the analog outputs The 9 pin DB female connector labelled SERIAL COMM is an RS422 control port for external control of the device and is typically connected to and MLC8BR REMOTE control p...

Page 3: ...ad been made Please note that a mix of signal types can not be controlled simultaneously When the sixth button in the cluster labelled ST MODE is pushed inputs one through six AES 1 2 and 3 and Analog 1 2 and 3 are disconnected the seventh and eighth channels AES4 and Analog4 are switched to the inputs 1 and 2 controls This allows the operator to listen to the ST L and ST R on the L and R monitor ...

Page 4: ...uttons simultaneously until the level indicator LEDs flicker approximately five seconds and the mix will be stored To recall the setup press and hold the ST MODE button approximately five seconds until the level indicating LEDs flicker MLC8BR Remote Panel The MLC8BR Remote Panel permits secondary control of the MLC8B from a remote location Controls and displays on the MLC8BR mimic those on the mai...

Page 5: ...MLC8B CONNECTOR LAYOUTS AES CONNECTOR ASSIGNMENT MLC8B INTERCONNECT CABLE ...

Page 6: ......

Page 7: ......

Page 8: ...MLC8B FUNCTIONAL DIAGRAM ...

Page 9: ...rminal Block AES EBU OUTPUTS Impedance 110Ω transformer balanced Level 2 5V p p terminated Output 0 dbfs Noise Less than 100 dbfs Standard AES31D 1995 THD Less than 0 001 Type 3 pin Terminal Block MONITOR OUTPUT Frequency Response 1 5 dBu from 20Hz to 20kHz Impedance 60Ω balanced Max Output 23 5 dBu Noise less than 70 dbfs THD Less than 0 05 Connector Type 3 pin Terminal Block POWER Input 90 230 V...

Page 10: ...ble such as fuses and lamps This warranty does not cover damages caused by misuse accident neglect unauthorized alteration repair by unauthorized personnel or damage caused by an act of God war or civil insurrection In no event shall Ward Beck Systems Ltd be liable for consequential damages Ward Beck Systems Ltd shall have the rights to final determination as to the application of this warranty Wa...