Unpacking:
Please inspect the unit carefully to ensure that damage had not occurred during
shipping.
Report any damage immediately to the factory, note if there is any obvious damage to
the packaging.
The unit is supplied with a full complement of Phoenix
™
3pin pluggable connectors
installed in their mating sockets. DB multipin type connectors and BNC connectors are
not supplied.
A standard 3pin disconnect IEC power cable is included.
Installation:
The MLC8B mounts in a standard 19 inch rack and occupies one rack unit of space.
Connections to the unit are made on the rear panel. Please note that the 25pin DB
female connector labelled
AUX 1
is used to connect the analog inputs while the 25pin
DB male connector labelled
AUX 2
is used to connect the analog outputs. The 9pin
DB female connector labelled
SERIAL COMM
is an RS422 control port for external
control of the device and is typically connected to and MLC8BR REMOTE control panel.
Please refer to the rear panel layout diagram and the detailed connector diagram for
connectors
AUX1, AUX2 and SERIAL COMM
.
The MLC8B is factory calibrated to operate at the nominal level of 20dBFS = 0. The
unit may be field calibrated for nominal levels of 18dBFS, 14dBFS or 12dBFS, please
refer to the calibration table in this manual.