background image

2

www.waynepumps.com

Operating Instructions and Parts Manual

INSTALLATION (CONTINUED)

SUCTION PIPING

 

Install foot valve or strainer screen over intake 

  of suction piping.

Never use pipe smaller than 2” in diameter for suction piping. The suction 

pipe must be kept free of air leaks. For horizontal runs, lay pipe from the 

water source so the upward slope is at least 1/4” per foot. This eliminates 

trapped air. The threaded inlet of the pump is 2” NPT.

 

Do not install suction piping near swimming 

 areas.

DISCHARGE PIPING

Install a 1-1/2” pipe tee in the pump discharge to allow easy priming. Plug 

the end of the tee opposite the pump to allow the branch piping to go to 

the spray nozzles (See Figure 1). Remove the pipe plug to fill the pump 

with water for priming. 

CONNECTION TO WATER SOURCE

The maximum vertical suction lift from pump to the water level is 25 feet. 

DRILLED WELL

1.  Install a foot valve on the first section of pipe (see Figure 2).
2.  Lower the pipe into the well.
3.  Add pipe until the foot valve is 10 feet below the lowest anticipated 

water level.

PIPE PLUG

TO SPRAY 

NOZZLES

SHORT 

SECTION 

OF PIPE

1-1/2” PIPE 

TEE

PUMP

Figure 1

TO PUMP

WELL

WELL 

CASING

FOOT 

VALVE

Figure 2

Leaking joints or couplings will allow air to leak into the pipe and cause 

poor pump operation or difficulty priming. Make sure to use pipe joint 

compound or plumber’s seal tape on all threaded pipe connections.

 

Locate foot valve no closer than 2 feet from the  

  bottom of the well so sand or sediment is not 

drawn into the system.

4.  After the proper depth is reached, install a well seal or pitless adapter 

to support the pipe.

5.  Slope the horizontal pipe upward toward the pump to eliminate 

trapping air.

6.  When using a foot valve, a priming tee and plug above the well seal 

is recommended.

DRIVEN WELL

•  Drive the point several feet below the water table.

NOTE:

 A packer-type foot valve can be installed in the well (See Figure 

3). This type of foot valve allows the well pipe to be filled with water when 

priming and makes the inlet pipe much easier to test for leaks. Follow the 

manufacturer’s instructions when installing the packer-type foot valve.

As an alternative, an in-line check valve can be used with a driven well 

(See Figure 4). 

DRIVE POINT

Figure 3

TO PUMP

PACKER 

TYPE FOOT 

VALVE

Summary of Contents for WLS Series

Page 1: ...y damage WILL result This pump is not designed to handle salt water brine laundry discharge or any other application which may contain caustic chemicals and or foreign materials Pump damage could occu...

Page 2: ...ticipated water level PIPE PLUG TO SPRAY NOZZLES SHORT SECTION OF PIPE 1 1 2 PIPE TEE PUMP Figure 1 TO PUMP WELL WELL CASING FOOT VALVE Figure 2 Leaking joints or couplings will allow air to leak into...

Page 3: ...e pump to a separate electrical circuit with a dedicated circuit breaker Refer to the electrical specifications in wiring chart for recommended fuse and wire size Install and maintain wiring for this...

Page 4: ...ack of the impeller is the brass colored threaded insert Remove the ceramic seal and rubber boot from the seal pate it is easier to remove the seal by unbolting the seal plate from the motor flange If...

Page 5: ...ocal building codes for recommendations and compliance Pipe Size inches PSI Friction Loss in 100 Feet of Pipe US Gallons per Hour 1200 1500 1800 2400 3000 3600 4800 6000 7200 1 25 2 6 3 9 5 5 9 4 14 1...

Page 6: ...ses Unscrew priming plug and see if water is in priming hole 1 Pump in new installation did not pick up prime through 1 New installation a Improper priming a Re prime according to instructions b Air l...

Page 7: ...n Drive Harrison OH 45030 U S A REPLACEMENT PARTS LIST Ref No Description Part Number Qty 1 WLS200 2 HP Kit Square Ring Impeller Diffuser Screws Shaft Seal Assembly 62063 WYN1 1 2 WLS150 1 5 HP Kit Sq...

Page 8: ...EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the...

Page 9: ...de choque el ctrico Esta bomba no es sumergible sela s lo para bombear agua limpia No la use para bombear l quidos inflamables o explosivos tales como gasolina combuestibles Kerosene etc No la use en...

Page 10: ...omba para cebarla CONEXION A LA FUENTE DE AGUA La altura m xima de succi n entre la bomba y el nivel de agua es de 7 6 metros 25 POZOS TALADRADOS 1 Instale una v lvula de pie en la primera secci n de...

Page 11: ...os CONECCIONES EL CTRICAS Conecte la bomba a un circuito el ctrico independiente con un disyuntor dedicado Consulte las especificaciones el ctricas de la tabla de cableado para ver el tama o recomenda...

Page 12: ...se un destornillador de paleta grande para sostener el eje del motor mientras desatornilla el impulsor Quite la parte del fuelle del sello del eje asegur ndose de que la manga de metal tambi n se reti...

Page 13: ...00 1150 WLS75 15 3100 2900 2750 2600 2450 20 2700 2550 2400 2200 2050 25 2350 2200 2000 1750 1450 30 1950 1700 1400 1000 500 TAMA OS DE CABLES Y FUSIBLES Para los tama os recomendados de cables y fusi...

Page 14: ...bomba en un sitio diferente la bomba no complet el proceso de cebado debido a 1 Instalaci n nueva a Cebado incorrecto a Siga las instrucciones para cebar la bomba b Fugas de aire b Chequ e todas las...

Page 15: ...OH 45030 U S A LISTA DE PARTES DE REPARACI N No de Ref Descripci n N mero de parte Ctd 1 Juego del WLS200 2 HP anillo cuadrado impulsor difusor tornillos ensamble del sello del eje 62063 WYN1 1 2 Jue...

Page 16: ...INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites en...