WLS Series

WIRE AND FUSE SIZES

For recommended Wire and Fuse Sizes, refer to your local building codes for recommendations and compliance.

Pipe Size 

(inches)

PSI Friction Loss in 100 Feet of Pipe

US Gallons per Hour

1200

1500

1800

2400

3000

3600

4800

6000

7200

1.25

2.6

3.9

5.5

9.4

14.1

22.0

1.5

1.2

1.9

2.6

4.4

6.7

9.4

17.5

2.0

0.6

0.8

1.3

2.0

2.8

4.7

7.1

10.0

2.5

0.6

0.8

1.2

2.0

3.1

4.3

Summary of Contents for WLS Series

Page 1: ...y damage WILL result This pump is not designed to handle salt water brine laundry discharge or any other application which may contain caustic chemicals and or foreign materials Pump damage could occu...

Page 2: ...ticipated water level PIPE PLUG TO SPRAY NOZZLES SHORT SECTION OF PIPE 1 1 2 PIPE TEE PUMP Figure 1 TO PUMP WELL WELL CASING FOOT VALVE Figure 2 Leaking joints or couplings will allow air to leak into...

Page 3: ...e pump to a separate electrical circuit with a dedicated circuit breaker Refer to the electrical specifications in wiring chart for recommended fuse and wire size Install and maintain wiring for this...

Page 4: ...ack of the impeller is the brass colored threaded insert Remove the ceramic seal and rubber boot from the seal pate it is easier to remove the seal by unbolting the seal plate from the motor flange If...

Page 5: ...ocal building codes for recommendations and compliance Pipe Size inches PSI Friction Loss in 100 Feet of Pipe US Gallons per Hour 1200 1500 1800 2400 3000 3600 4800 6000 7200 1 25 2 6 3 9 5 5 9 4 14 1...

Page 6: ...ses Unscrew priming plug and see if water is in priming hole 1 Pump in new installation did not pick up prime through 1 New installation a Improper priming a Re prime according to instructions b Air l...

Page 7: ...n Drive Harrison OH 45030 U S A REPLACEMENT PARTS LIST Ref No Description Part Number Qty 1 WLS200 2 HP Kit Square Ring Impeller Diffuser Screws Shaft Seal Assembly 62063 WYN1 1 2 WLS150 1 5 HP Kit Sq...

Page 8: ...EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the...

Page 9: ...de choque el ctrico Esta bomba no es sumergible sela s lo para bombear agua limpia No la use para bombear l quidos inflamables o explosivos tales como gasolina combuestibles Kerosene etc No la use en...

Page 10: ...omba para cebarla CONEXION A LA FUENTE DE AGUA La altura m xima de succi n entre la bomba y el nivel de agua es de 7 6 metros 25 POZOS TALADRADOS 1 Instale una v lvula de pie en la primera secci n de...

Page 11: ...os CONECCIONES EL CTRICAS Conecte la bomba a un circuito el ctrico independiente con un disyuntor dedicado Consulte las especificaciones el ctricas de la tabla de cableado para ver el tama o recomenda...

Page 12: ...se un destornillador de paleta grande para sostener el eje del motor mientras desatornilla el impulsor Quite la parte del fuelle del sello del eje asegur ndose de que la manga de metal tambi n se reti...

Page 13: ...00 1150 WLS75 15 3100 2900 2750 2600 2450 20 2700 2550 2400 2200 2050 25 2350 2200 2000 1750 1450 30 1950 1700 1400 1000 500 TAMA OS DE CABLES Y FUSIBLES Para los tama os recomendados de cables y fusi...

Page 14: ...bomba en un sitio diferente la bomba no complet el proceso de cebado debido a 1 Instalaci n nueva a Cebado incorrecto a Siga las instrucciones para cebar la bomba b Fugas de aire b Chequ e todas las...

Page 15: ...OH 45030 U S A LISTA DE PARTES DE REPARACI N No de Ref Descripci n N mero de parte Ctd 1 Juego del WLS200 2 HP anillo cuadrado impulsor difusor tornillos ensamble del sello del eje 62063 WYN1 1 2 Jue...

Page 16: ...INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites en...

Reviews: