GENERAL SAFETY INFORMATION (CONT’D)

  Use safety equipment. Always wear eye 

protection. Dust mask, non-skid safety shoes and hard hat must be 
used for appropriate conditions.

  Utiliser un équipement de sécurité. Toujours 

porter des lunettes de protection. Un masque anti-poussière, des 
chaussures de sécurité antidérapantes et un casque doivent être 
utilisés selon les conditions appropriées.

  If using pump to drain a vessel containing 

heated water, allow time for water time to cool to ambient temperature 
before pumping the water. Failure to do so may cause pump failure or 
property damage and will void warranty.

  Lors de l’utilisation d’une pompe pour vider 

un réservoir contenant de l’eau chaude, laisser l’eau refroidir jusqu’à 
température ambiante avant de la pomper. Ne pas le faire peut entraîner 
une panne de la pompe ou des dégâts matériels et annulera la garantie.

  This product is not approved for 

permanent pool applications or as a pool or spa-cover drain 
pump.

  Ce produit n’est pas approuvé pour une 

utilisation permanente en piscine ou comme pompe de vidange de 
piscine ou de cuve thermale.

 

If there is water or moisture on the fl oor, do not 

walk on wet area until all power is turned off. If the shut-off box is in 
the basement, call an electrician. Failure to follow this warning could 
result in fatal electrical shock.

 

Si le sous-sol a de l’eau ou de l’humidité sur 

le plancher, ne pas marcher aux endroits mouillés avant que le courant 
ne soit coupé. Si le boîtier de coupure de courant se trouve au sous-
sol, appeler un électricien. Le non-respect de cet avertissement peut 
entraîner un choc électrique mortel.

 

Disconnect power before servicing. Improper 

use could result in death or serious injury.

 

Débrancher l’alimentation avant de procéder 

à l’entretien. Une utilisation incorrecte peut entraîner la mort ou des 
blessures graves.

 

DO NOT handle a pump or pump motor with 

wet hands or when standing on wet or damp surface or in 
water when pump is connected to power source.

 

NE PAS manipuler une pompe ou 

un moteur de pompe avec des mains mouillées ou sur 
une surface mouillée ou humide ou dans l’eau lorsque la pompe est 
connectée à une source d’alimentation.

PUMP OPERATION

 1.  This pump has been designed  to attach to a standard 

garden hose. Thread the female end of the garden 
hose to either discharge on the pump. Make sure the 
discharge not being used is securely sealed using the 
attached screw-on cap (if unused discharge is not 
capped, water will not be pumped through the garden 
hose).

 2.  To reduce leakage between the pump and the hose, 

place a hose washer (not included) on the garden hose 
before attaching to the pump.

 3.  For best pump performance, unwind the hose before 

starting the pump. This will help remove any kinks or 
binds in the hose and allow the unit to pump with less 
restriction.

 4.  Place pump on a hard surface in the water. Do not set 

the pump directly on mud or sand surfaces. This will 
cause the inlet screen to clog. For best results clean 
an area on the hard surface for the pump to sit while 
working. The filter features of this pump work best if 
the debris is filtered from the outside in. Sitting the 
pump directly on a loose/dirty surface will not allow the 
filter features to work to their full extent.  

NOTE: 

A flat object such as a piece of hardwood or rigid   

plastic (e.g. 5 gallon bucket lid) can be placed  

 

under the pump if no clean hard surface can be found.  
However, this will increase the priming and pump down 
levels. 

  Do not place pump directly on clay, gravel, 

leaves or any loose or sandy surfaces. These surfaces contain small 
stones, sand, or debris that may clog or damage the pump. This could 
result in pump failure causing fl ooding and property damage. 

5. The water level must be at least 3/16 inch deep for the 

pump to operate. Water levels less than 3/16 inch will 
not allow the impeller to contact water and no water 
will be pumped.

 6.  Inspect the pump housing, power cord, and plug for 

damage or leaks. If the plug is missing the grounding 
prong or the cord is damaged, do not use the pump. 
If the pump housing is damaged or leaking discard 
pump. DO NOT USE.

  Never cut off grounding prong or use an 

adapter, this will void warranty.

  Ne jamais débrancher la broche de mise à la 

terre ou utiliser un adaptateur, cela annulera la garantie.

SPECIFICATIONS

POWER SUPPLY REQUIREMENTS

   120 V, 60 Hz 

MOTOR

   Single Phase, Dielectric Oil Filled

HORSEPOWER                                                         

1/6 HP

CIRCUIT REQUIREMENT                                         

15 A (minimum)

LIQUID TEMPERATURE RANGE                              

40° F- 120° F

© 2018, WAYNE/Scott Fetzer Company.

CONSTRUCTION

MOTOR HOUSING

Thermoplastic

MOTOR SHAFT

Stainless Steel

IMPELLER

Thermoplastic

PUMP DISCHARGE

(2) 3/4 in. Brass Hose Fittings

www.waynepumps.com

PERFORMANCE

Model

HP

Discharge Head

 

0 ft.

5 ft.

10 ft.

15 ft.

20 ft.

25 ft.

WWB 2

1/6

Gal/hr

1350

1190

1010

815

600

350

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or 
maintain the product described. Protect yourself and others by observing all safety information. Failure 
to comply with instructions could result in personal injury and/or propertydamage! Retain instructions 
for future reference.