Operating Instructions

GENERAL SAFETY INFORMATION (CONTINUED)

 

power cord plug directly into a properly installed and grounded 
3-prong (GFCI), ground ing-type re cep ta cle (as shown in Fig ure 1).

 

Where a 2-prong wall receptacle is en coun tered, it must be re placed 
with a properly grounded 3-prong (GFCI) re cep ta cle installed in 
accordance with the NEC and local codes and ordinances.

13.  All wiring should be performed by a qualified electrician.

 

The pump motor is equipped with an automatic 

  resetting thermal protector and MAY restart 

unexpectedly. Protector tripping is an indication of motor overheating as 

a result of operating the pump at low head (low discharge restriction), 

excessively high or low voltage, inadequate wiring, excessive water 

temperature, inadequate water supply, excessive surrounding air 

temperature, bound impeller / motor,  

or a defective motor or pump.

14.  Protect electrical cord from sharp ob jects, hot sur fac es, oil, and 

chemicals. Avoid kinking the cord. Replace damaged or worn cords 
immediately.  Wiring must be of ad e quate size to min i mize voltage 
drop at the motor.

15.  Do not handle a pump or pump motor with wet hands or when 

standing on a wet or damp surface, or in water.

 

If your basement or room has water or moisture 

  on the floor, do NOT walk on wet area until all 

power has been turned off. If the shut-off box is in the basement, call 

the electric company to shut-off service to the house, or call your local 

fire department for instruction. Failure to follow this warning WILL result 

in fatal electrical shock.

APPLICATION

Important:

 This pump is not designed for use in septic tanks or 

underground vaults to handle raw sewage or gray water. It should never 
be used in hazardous or explosive locations. Do not use power cord or 
discharge hose to lift pump. Always use the handle.
1.  Pump should be located and should rest on a level solid foundation. 

Pump requires 2-5/8 in. of water minimum to operate. Do not 
suspend pump by means of the dishcarge pipe or power cord. 
Keep pump inlet screen clear. Do not place pump directly on clay, 
earth or sand sur fac es. Protect pump from extreme heat and cold. 
Use pipe joint seal ant to ensure airtight pipe con nec tions.

2.  Thread discharge (outlet) pipe into pump body care ful ly to avoid 

stripping or cross threading.

3.  To install garden hose, install the elbow adapter provided with the 

pump. The elbow adapter uses a o-ring seal to provide better water 
removal. Rotate the elbow adapter until the o-ring seals against the 
pump body and the discharge is in the desired direction. Thread 
garden hose onto the elbow fitting.

NOTE:

 The garden hose must be 3/4 in. or larger to keep friction as low 

as possible.
A 1-1/4 in. sump discharge hose adapter can be connected directly to 
the pump body using plumber’s seal tape.
4.  Run discharge pipe/hose away from the pump.
5.  It is required that this unit is plugged into a Ground Fault Circuit 

In terrupt er (GFCI). Con sult a local electrician for installation and 
availability.

Power Supply: Pump is designed for 120 volt, 60 Hz operation and 
requires a circuit of 15 amp minimum capacity. Pump is supplied with 
a 3-wire cord set with ground ing-type plug for use in a 3-wire (GFCI), 
grounded outlet.

 Do 

NOT cut off the round grounding prong. 

  Cutting cord or plug WILL void warranty and 

MAY make pump inoperable.

6.  Do not bend, kink or cut power cord. Protect cord from sharp 

objects, hot sur fac es, oil and chemicals. Re place damaged cord.

7.  After all piping and controls have been installed, unit is ready for 

operation.

OPERATION

 Do 

NOT touch pump, pump motor, 

  water or discharge piping when 

the pump is connected to electrical power. Do NOT handle 

a pump or pump motor with wet hands or when standing 

on wet or damp surface, or in water. NEVER touch the pump 

or discharge piping when unit is operating or fails to operate. ALWAYS 

disconnect the pump cord (power) before handling.
 

Risk of electrical shock! This pump  

  is supplied with a grounding 

conductor and grounding type attachment plug. Use a 

grounded (GFCI) receptacle to reduce the risk of fatal 

electrical shock.

This pump is designed for 120 Volt, 60 Hz operation and requires a 
15 amp circuit or more and is equipped with a 3-wire cord set with a 
grounding-type plug for use in a 3-wire ground ed (GFCI) outlet. For safety, 
this pump should always be electrically grounded to a suitable electrical 
ground. NEVER cut off the round grounding plug.
1.  Pump should never be allowed to run dry. Shaft seal depends 

on water for lu bri ca tion. Do not operate the pump unless it is 
submerged in water. Dry run ning (pump not pumping water) will 
cause seal damage and eventual pump failure.

2.  Plug unit into 120 volt GFCI outlet.
3.  The motor is equipped with an automatic reset ther mal protector. 

This means if the temperature in the motor should rise unduly, the 
protector will cut off all power before damage can be done to the 
motor. When the motor has cooled sufficiently, the switch will reset 
automatically and restart the motor. If protector trips repeatedly 
(cycling of protector) pump should be removed and checked. Low 
head (low discharge restriction), excessively high or low voltage, 
inadequate wiring, excessive water temperature, inadequate water 
supply, excessive surrounding air temperature, bound impeller/

TEST RESET

Figure 1

GROUNDING 

BLADE

GFCI OUTLET

Summary of Contents for VIP Series

Page 1: ...uipment 2 Know the pump application limitations and potential hazards Read these rules and the instructions carefully Failure to follow them could cause serious bodily injury and or property damage Do...

Page 2: ...direction Thread garden hose onto the elbow fitting NOTE The garden hose must be 3 4 in or larger to keep friction as low as possible A 1 1 4 in sump discharge hose adapter can be connected directly...

Page 3: ...LESHOOTING CHART Symptom Possible Cause s Corrective Action Pump will not start or run 1 Blown fuse or tripped circuit breaker 1 If blown replace with proper sized fuse or re set break er 2 Low line v...

Page 4: ...ns might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of c...

Page 5: ...la aplicaci n limitaciones y posibles riesgos de la bomba Lea estas reglas e instrucciones cuidadosamente El no seguirlas podr a causar graves lesiones corporales y o da os a la propiedad No BOMBEE l...

Page 6: ...ire el adaptador acodado hasta que el anillo en O quede sellado contra el cuerpo de la bomba y la descarga se encuentre en la direcci n deseada Enrosque la manguera de jard n en la conexi n acodada NO...

Page 7: ...l ctrico de motor para su lubricaci n y la transferencia de calor del motor Este aceite PUEDE ser da ino para el medio ambiente Verifique las leyes ambientales del estado antes de eliminar este aceite...

Page 8: ...un estado a otro Bajo ninguna circunstancia aunque sea debido al incumplimiento del contrato de garant a culpabilidad in cluyendo negligencia u otras causas la compa a Wayne o ninguno de sus surtidor...

Reviews: