background image

1/3 HP Sink Pump 
System

 Description

 This system pumps water up to an 
existing water drain and is designed for 
residential use in laundry trays, washing 
machines, wet bar sinks, sinks and tubs, 
dehumidifiers, and air conditioners. 
The submersible sump pump included 
in this system is equipped with an 8-ft 
long, 3-prong grounding type power 
cord. Motor is oil filled and sealed for 
cooler running and designed to operate 
under water. A float switch is provided 
for automatic pump operation. This 
pump is not suitable for aquatic life.

Unpacking

Inspect this unit before it is used. 
Occasionally, products are damaged during 
shipment. If the pump or components 
are damaged, call our customer service 
department at 1-800-237-0987.

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates an

 imminently 

hazardous situation which, if not avoided, 
WILL result in death or serious injury.

 

Warning indicates a 

 potentially 

hazardous situation which, if not avoided, 
COULD result in death or serious injury.

 

Caution indicates a 

 potentially 

hazardous situation which, if not avoided, 
MAY result in minor or moderate injury.

 Notice 

indicates 

 important 

information, that if not followed, MAY 
cause damage to equipment.

local electrician for installation and 
availability.

7.  This pump is designed to transfer 

water in cycles. Using this pump in 
a continuous duty application by 
ma nip u lat ing the switch to stay on, 
will effect the per for mance and the 
life of the product.

8.  Protect electrical cord from sharp 

objects, hot sur fac es, oil, and 
chemicals. Avoid kinking the cord. 
Re place or repair damaged or worn 
cords im me di ate ly. Use wire of 
adequate size to minimize voltage 
drop at the motor.

9.  Do not handle a pump or pump motor 

with wet hands or when standing on a 
wet or damp surface, or in water.

 Do 

NOT 

 walk 

on 

wet area until all power has 
been turned off. If the shut-off 
box is in basement, call the 
electric company to shut-off service to the 
house, or call the local fi re department for 
instructions. Remove pump and repair or 
replace. Failure to follow this warning can 
result in fatal electrical shock.

Assembly

Assembly Instructions:

1.  Remove packaging, including the 

foam inside the tank.

2.  Apply gasket to top of tank, just 

outside the opening. (See Figure 1)

General Safety
Information

CALIFORNIA PROPOSITION 65

 

This product or 

  its power cord may 

contain chemicals known to the State 
of California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.

 GENERAL SAFETY INFORMATION

1.  Know the pump application, 

limitations, and po ten tial hazards.

 Do 

NOT

 use 

to 

pump fl ammable or explosive 
fl uids such as gasoline, fuel oil, 
kerosene, etc. Do NOT use in 
fl ammable and/or explosive atmospheres. 
Use pump only with liquids compatible 
with pump component materials. Failure 
to follow this warning can result in 
personal injury and/or property damage.

                                      Disconnect 

  power 

before servicing. If the power 
dis con nect is out of sight, lock 
in the open po si tion and tag 
it to prevent unexpected application of 
power. Failure to do so could result in fatal 
electrical shock!

2.  Drain all liquids from the system 

before servicing.

3.  Periodically inspect the pump 

and system com po nents. Perform 
routine maintenance as required 
(See maintenance section).

4. When wiring an elec tri cal ly driven 

pump such as this, fol low all 
electrical and safety codes, as well as 
the most recent National Electrical 
Code (NEC) and the Oc cu pa tion al 
Safety and Health Act (OSHA).

5.  All wiring should be performed by a 

qualified elec tri cian.

6.  It is strongly recommended that this 

unit is plugged into a Ground Fault 
Circuit Interrupter (GFCI). Con sult a 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain 
the product described. Protect yourself and others by observing all safety information. Failure to comply with 
instructions could result in personal injury and/or property damage! Retain instructions for future reference.

For parts, product & service information

visit 

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

332800-001 3/11

Operating Instructions & Parts Manual  

SYLT30

© 2011, WAYNE Water Systems/Scott Fetzer.

Figure 1: Adding Lid Gasket to Tank

Summary of Contents for SYLT30

Page 1: ...ll the local fire department for instructions Remove pump and repair or replace Failure to follow this warning can result in fatal electrical shock Assembly Assembly Instructions 1 Remove packaging in...

Page 2: ...y System See Figure 4 Insert pipe 2 to 3 inches into vent opening 3 Connect Intake of this Laundry Tray System See Figure 4 to your washing machine or other source The threads are 1 1 2 in NPT 2 Opera...

Page 3: ...by adding water to the inlet The pump will start automatically when the water has filled the reservoir to a depth of approximately 9 inches The pump will stop when the water depth is approximately 4 i...

Page 4: ...om piping 2 Faulty float switch 1 Replace check valve 2 Replace float switch Recommended for at least every 2 years Pump will not shut off or thermal protector turns off 1 Defective float switch 2 Obs...

Page 5: ...tzer Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A SYLT30 Reference Number Description Part Number Quantity 1 Impeller 60138 001...

Page 6: ...allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limite...

Page 7: ...des directives Enlever la pompe et la r parer ou la remplacer Ne pas suivre ces conseils peut r sulter en choc lectrique mortel Assemblage Instructions d assemblage 1 Retirer l emballage incluant la m...

Page 8: ...lessive Voir la Figure 4 Ins rer 50 8 7 6 mm 2 3 po de tuyau dans l ouverture d vent 3 Brancher l entr e de ce syst me de plateau de lessive Voir la Figure 4 votre laveuse ou une autre source Les fil...

Page 9: ...ra automatiquement lorsque l eau remplit le r servoir une profondeur d environ 23 cm 9 po La pompe s arr tera lorsque la profondeur d eau sera d environ 10 2 cm 4 po La pompe reprendra son cycle par l...

Page 10: ...errupteur flotteur d fectueux 1 Remplacer le clapet 2 Remplacer l interrupteur flotteur Recommand pendant au moins tous les 2 ans Pompe ne s arr te pas ou le protecteur thermique s teint 1 Interrupteu...

Page 11: ...eur 60140 001 1 6 Montage de la pompe pompe et interrupteur 58325 002 1 Pour Pi ces de Rechange ou Assistance Technique Appeler 1 800 237 0987 S il vous pla t fournir l information suivante Adresser t...

Page 12: ...e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e donne l acheteur d...

Page 13: ...mblaje Instrucciones de ensamblaje 1 Quite el envoltorio junto con la espuma que se encuentra dentro del tanque 2 Aplique la junta a la parte superior del tanque justo por debajo de la abertura Ver Fi...

Page 14: ...tuber a por la abertura de ventilaci n de 5 08 a 7 62 cm 2 a 3 pulg 3 Conecte la entrada de este sistema de pileta de lavado Ver Figura 4 a su lavadora u otra fuente Las roscas son de 3 81 cm 1 1 2 pu...

Page 15: ...bomba se iniciar autom ticamente cuando el agua haya llenado el dep sito hasta una profundidad de 22 86 cm 9 pulg La bomba se detendr cuando la profundidad del agua sea de 10 16 cm 4 pulg aproximadame...

Page 16: ...e la v lvula de retenci n 2 Cambie el interruptor de flotador Se recomienda por lo menos cada 2 a os La bomba no se apaga o el protector t rmico se apaga 1 Interruptor de flotador defectuoso 2 Obstruc...

Page 17: ...001 1 6 Ensamble de la bomba bomba y interruptor 58325 002 1 Para Ordenar Repuestos o Asistencia T cnica llame 1 800 237 0987 Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a...

Page 18: ...Sp 18 Manual de Instrucciones y Repuestos Notas...

Page 19: ...SYLT30 Notas Sp 19...

Page 20: ...DA OS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mi...

Reviews: