background image

12

www.waynepumps.com

Summary of Contents for RPP50

Page 1: ...Reinforced Thermoplastic SEL50 EFL50 Glass Reinforced Thermoplastic IMPELLER Glass Reinforced Thermoplastic SHAFT Steel DISCHARGE 2 in NPT Sewage Effluent Pumps PERFORMANCE Model HP Discharge Head 0 f...

Page 2: ...ire le risque de choc lectrique s assurer qu elle est branch e seulement une prise de courant correctement mise la terre FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit i...

Page 3: ...ACHEMINEMENT D EAU DESTIN E LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilis e comme de l eau potable destin e la consommation La pompe doit tre utilis e uniquement...

Page 4: ...PUMP SHOULD BE USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU LEV OU UNE POMPE DE SAUVEGARDE DOIVENT TRE UTILIS ES en cas de risque de d g ts mat...

Page 5: ...tructions 6 Install discharge plumbing according to local regional and state codes Do not reduce the discharge pipe size below that which is provided on the pump 7 If optional control device or float...

Page 6: ...uld be installed above the check valve as required by local regional or state codes 10 Connect remaining discharge pipe The remainder of the discharge line should be as short as possible with a minimu...

Page 7: ...n of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjustment...

Page 8: ...p 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE MAINTENANCE The pump should be inspec...

Page 9: ...RRANTY SERVICE PARTS SHEET REPLACEMENT PARTS REPAIR KITS REF NO DESCRIPTION MODELS Sewage RPP50 SEL50 WCS50T Effluent EFL50 1 TETHER SWITCH ALL MODELS 56835 WYN1 2 10 FT CORD WCS50T ONLY 31006 WYN2 9...

Page 10: ...s Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayn...

Page 11: ..._____________________________________________________________________________________________ _____________________________________________________________________________________________ ___________...

Page 12: ...12 www waynepumps com...

Reviews: