INSTALLATION MANUAL

5

Submersible Sewage 
Pumps

1

3

5

2

7

6

4

8

9

10

11

1.  Check Valve

7. Switch

2. Union

8.  Minimum Diameter (18 in.)

3.  Discharge Pipe

9.  Minimum Depth (24 in.)

4.  Inlet Pipe

10.  Gasket/Basin Lid

5.  Basin/Septic Tank

11.  Vent Pipe

6.   Pump (RPP50, 

SEL50, WCS50T)

ON LEVEL  

(RPP50-APPROX. 16 IN.
SEL50-APPROX. 17 IN.
WCS50T-APPROX. 19 IN.)
 

OFF LEVEL 
(RPP50-APPROX. 7.5 IN.
SEL50-APPROX. 7 IN.
WCS50T-APPROX. 10.5 IN.)

18 IN. DIAMETER MIN.

24 IN. DEPTH MIN.

TYPICAL SEWAGE INSTALLATION

1.  This installation must be in accordance with the National 

Electric Code and all applicable local codes and 
ordinances.

2.  Use a basin that is large enough to accommodate the 

pump. The basin diameter should be a minimum of 18 
inches and the depth a minimum of 24 inches.

3.  Clean the basin of all debris. 

4.  Set the pump on a solid, level surface. Do not place pump 

directly on clay, earth, gravel, or sand. A brick or block may 
be installed under the pump to provide a solid base.

5.  Position pump in the basin so the switch is away from 

incoming water. Verify the float switch has at least 1 inch 
clearance to the side wall of the basin and is free of any 
possible obstructions.

6.  Install discharge plumbing according to local, regional and 

state codes. Do not reduce the discharge pipe size below 
that which is provided on the pump.

7.  If optional control device or float is used, follow mounting 

instruction supplied with device or float. 

8.    A union should be installed above the basin to allow easy 

removal of the pump for cleaning and service.

9.  Install a check valve (required) to prevent back-flow. 

It should be installed above the union.

10.  A gate valve or ball valve should be installed above the 

check valve as required by local, regional or state codes.

11.  Connect remaining discharge pipe. The remainder of 

the discharge line should be as short as possible with a 
minimum number of turns.

12.  A vent pipe is required. It removes gases and odors and 

should be installed as required by local, regional or state 
codes.

13.  Secure power supply cord to discharge pipe using cable or 

zip ties to prevent possible switch entanglement. 

14.  Connect pump power supply cord to a ground fault circuit 

interrupter (GFCI) receptacle.

15.  Fill the basin with water. The pump will start when the 

water level has reached the switch-on level. Verify the 
pump is operating normally.

16.  Install a basin cover and gasket to prevent debris from 

falling into the basin, prevent personal injury and to contain 
gases and odors.

Summary of Contents for RPP50

Page 1: ...Reinforced Thermoplastic SEL50 EFL50 Glass Reinforced Thermoplastic IMPELLER Glass Reinforced Thermoplastic SHAFT Steel DISCHARGE 2 in NPT Sewage Effluent Pumps PERFORMANCE Model HP Discharge Head 0 f...

Page 2: ...ire le risque de choc lectrique s assurer qu elle est branch e seulement une prise de courant correctement mise la terre FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit i...

Page 3: ...ACHEMINEMENT D EAU DESTIN E LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilis e comme de l eau potable destin e la consommation La pompe doit tre utilis e uniquement...

Page 4: ...PUMP SHOULD BE USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU LEV OU UNE POMPE DE SAUVEGARDE DOIVENT TRE UTILIS ES en cas de risque de d g ts mat...

Page 5: ...tructions 6 Install discharge plumbing according to local regional and state codes Do not reduce the discharge pipe size below that which is provided on the pump 7 If optional control device or float...

Page 6: ...uld be installed above the check valve as required by local regional or state codes 10 Connect remaining discharge pipe The remainder of the discharge line should be as short as possible with a minimu...

Page 7: ...n of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjustment...

Page 8: ...p 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE MAINTENANCE The pump should be inspec...

Page 9: ...RRANTY SERVICE PARTS SHEET REPLACEMENT PARTS REPAIR KITS REF NO DESCRIPTION MODELS Sewage RPP50 SEL50 WCS50T Effluent EFL50 1 TETHER SWITCH ALL MODELS 56835 WYN1 2 10 FT CORD WCS50T ONLY 31006 WYN2 9...

Page 10: ...s Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayn...

Page 11: ..._____________________________________________________________________________________________ _____________________________________________________________________________________________ ___________...

Page 12: ...12 www waynepumps com...

Reviews: