5
SERVICE TECHNICIAN INFORMATION
The information in this section is provided for Wayne certified service technicians only
.
5.1 DIP Switch Settings
DIP switches are on the control board as shown below. Turn off the power before setting DIP
switches.
The function of each switch is as follows:
Switch No.
Function
ON
OFF
Initial Settings
1
Auto Cut
Enabled
Disabled
ON
2
Hand shake
XON/XOFF
DTR/DSR
ON
3
Bit length
7 bits
8 bits
OFF
4
Parity check
With parity
None
OFF
5
Parity selection
Even parity
Odd parity
OFF
6
Baud rate selection
See Table below
ON
7
ON
8
Print density selection
Dark
Standard
OFF
Baud rate selection
Baud rate (bps)
Switch No.
6
7
9600
OFF
OFF
19200
ON
OFF
38400
OFF
ON
115200
ON
ON
Note:
For dispensers with QCAT board, set Switch 6 to OFF and Switch 7 to ON (38400 Baud rate).
For dispensers with iX board, set Switch 6 to ON and Switch 7 to ON (115200 Baud rate).
8 7 6 5 4 3 2 1 ON
14
____________________________________________________________________________
________
P/N 000-920921- Rev 0D 04/2015