Wayne CDUCAP Series Operating Instructions And Parts Manual Download Page 2

3 . Thread check valve (not included)

into pump body carefully to avoid
stripping or cross threading. Do not
use pipe joint sealant.

4 . Connect 1-1/4” (minimum) rigid pipe

to check valve.

Support pump 
and piping when

assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.

5 . Protect electrical cord from sharp

object, hot surfaces, oil and chemicals.
Avoid kinking the cord and replace
damaged cords immediately.

6. Position Pump switch AWAY from

the inlet so switch is clear from
incoming water (See Figure 1).

7. A sump pit cover must be installed

to prevent debris from clogging or
damaging the pump.

O p e r a t i o n

Always

disconnect the power source
before attempting to install,
service, relocate or maintain
the pump. Never touch sump
pump, pump motor, water or discharge
piping when pump is connected to
electrical power. Never handle a pump
or pump motor with wet hands or when
standing on wet or damp surface or in
water. Fatal electrical shock could occur.

1 . A ground fault circuit interrupter

(GFCI) is required.

Risk of electrical 
shock! This pump is

supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.

Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.

2 . This pump is only for use on 120 Volt

(single-phase), 60 hz, 15 amp service
and is equipped with a 3-conductor
cord and 3-prong, grounding type
plug. Insert the switch cord plug
directly into a 120 volt outlet.

General Safety
I n f o rmation (Cont.)

G E N E R A L

Do not 
use to

pump flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.

This pump is not 
designed to handle

salt water, brine, laundry discharge or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.

All wiring must be 
performed by a

qualified electrician.

If the 
basement

has water or moisture on the
floor, do not walk on wet
area until all power is turned
off. If the shutoff box is in
the basement, call an
electrician. Remove pump and either
repair or replace. Failure to follow this
warning could result in fatal electrical
shock.

A backupsystem 
should be used. 

Call 1-800-237-0987 for backup model
number.

Installation

1 . Install pump in a sump pit with

minimum size as shown in Figure 1.
Construct sump pit of tile, concrete,
steel or plastic.

2 . The unit should be located and rest

on a solid, level foundation. Do not
place pump directly on clay, earth,
gravel or sandy surface. These
surfaces contain small stones, gravel,
sand, etc. that may clog or damage
the pump and cause pump failure.

Flood risk. If 
flexible discharge

hose is used, make sure pump is
secured in sump pit to prevent
movement. Failure to secure pump
could allow pump movement and
switch interference and prevent pump
from starting or stopping.

2

Operating Instructions And Parts Manual

3 . Insert the pump power cord plug

directly into the back of the water
sensor cord plug (Figure 2).

4 . Fill sump with water. The pump will

start automatically when the water is
about 1.5” from the top of the
switch. The pump will recycle
thereafter as required.

• Sump pump will run a minimum of

4 seconds, to a maximum of 16
before stopping.

• Sump pump run time will be 

determined by the sump pit size
and water flow rate into the sump
p i t .

• Under flooding conditions, the 

sump pump will stop for 1 second, 
every 16 seconds, and
automatically turn back on.

5 . Do not operate the pump unless it is

submerged in water. Dry running
causes pump failure.

6 . The motor is equipped with an

automatic reset thermal protector.  

7 . While the pump is draining the pit,

verify that the discharge piping is
carrying the water to a point several
feet away from the foundation.

8 . If pump discharge line is exposed to

freezing temperature, the exposed
line must be pitched to drain.
Trapped water will freeze and
damage the pump.

w w w .waynepumps. c o m

Figure 2 – Switch Genius™ Water Sensor

Working surface of
sensor to be kept
free of foreign
material.

Summary of Contents for CDUCAP Series

Page 1: ...may cause damage to equipment General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals including lead known to the State of California to cause cancer...

Page 2: ...ials Pump damage could occur if used in these applications and will void warranty All wiring must be performed by a qualified electrician If the basement has water or moisture on the floor do not walk...

Page 3: ...the state environmental laws before disposing this oil www waynepumps c o m Troubleshooting Chart Symptom Possible Cause s Corrective Action Pump will not start or run Pump starts and stops too often...

Page 4: ...r as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A www waynepumps c o m 1 2 3 4 5 6 7 Replacement Parts List 1 Top cover kit 6003...

Page 5: ...CDUCAP Series 5 www waynepumps c o m Notes...

Page 6: ...ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclus...

Page 7: ...t G n ralit s sur la S curit POSITION 65 DE CALIFORNIE Ce produit ou son cordon peuvent contenir des produits chimiques y compris du plomb relev s par l tat de Californie comme cause de cancer d anoma...

Page 8: ...e mener des dommages la propri t et ou des blessures 5 Prot ger le cordon lectrique des objets tranchants des surfaces chaudes de l huile et des produits chimiques viter le tortillement du cordon et r...

Page 9: ...a figure 2 Cette pompe contient de l huile di lectrique pour son refroidissement Cette huile peut tre dangereuse pour l environnement V rifier les lois environnementales de l tat avant de jeter cette...

Page 10: ...scription et num ro de pi ce d apr s la liste de pi ces Correspondance Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A 1 2 3 4 5 6 7 1 N c de couvercle sup rieur 60030 001 2 Stator 3...

Page 11: ...11 Fr Notes CDUCAP S rie...

Page 12: ...N IMPORTE QUEL ET TOUT DOMMAGES INDIRECTS OU D PENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limit...

Page 13: ...s sto le indica una informaci n importante que de no seguirla le podr a ocasionar da os al equipo Bomba Sumergible para Sumideros 2008 Wayne Water Systems Especificaciones Requisitos de suministro de...

Page 14: ...laci n El no hacerlo podr a provocar que la tuber a se rompa que la bomba falle etc lo que podr a dar como resultado da o a la propiedad y o lesiones personales 5 Proteja el cable de corriente de obje...

Page 15: ...ue el ctrico mortal 1 Deje que la bomba se enfr e por no menos de dos horas antes de dar servicio puesto que la bomba contiene aceite caliente bajo presi n y el motor est caliente 2 Desensamblar el mo...

Page 16: ...d de repuestos a la siguiente direcci n Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A 1 2 3 4 5 6 7 1 Juego de cubierta superior 60030 001 2 Stator 3 Ensamble del rotor abrazadera i...

Page 17: ...sible del tama o correcto o reajuste el disyuntor 2 Si el voltaje est por debajo de 108 voltios verifique el tama o del cable 3 Reemplace la bomba 4 Si el impulsor no funciona retire la caja y quite l...

Page 18: ...18 Sp Manual de Instrucciones de Operaci n y Piezas Notas...

Page 19: ...CIVIL SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algunos estados no permiten l mites en la duraci n de las garant as o no permiten que se limiten o excluyan casos por da os por a...

Page 20: ...Operating Instructions And Parts Manual Instructions d Utilisation et Manuel de Pi ces Manual de Instrucciones de Operaci n y Piezas CDUCAP Series 20 Sp Notes Notas...

Reviews: