Wayne 370100-001 Operating Instructions Manual Download Page 1

Caution indicates a 
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates 
indicates important

information, that if not followed, may
cause damage to equipment.

General Safety
Information

1. Know the pump application,

limitations, and po ten tial hazards.

Do not
use to

pump flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in flammable and/or explosive
atmospheres. Use pump only with liquids
compatible with pump component
materials. Failure to follow this warning
can result in personal injury and/or
property damage.

2. Make certain that the power supply

conforms to the requirements of
the unit.

Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock

Please read and save these instructions. Read carefully
before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by
observing all safety information. Failure to comply with
instructions could result in personal injury and/or property
damage! Retain instructions for future reference.

Description

A condensate unit removes
condensation from air conditioning
and high efficiency furnaces. The
compact design of the unit consists of a
3/8” ID discharge and 6 ft. long power
cord. The unit also contains a safety
switch to automatically shut off pump
in the event of a failure.

Unpacking

Inspect this unit before it is installed.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

This pump is not
designed to handle

salt water, brine, laundry discharge, or
any other application which may contain
caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will void
warranty. Use for clear water application
only.

Safety Guidelines

This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols. 

Danger indicates 
an imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially

hazardous situation which, if not avoided,
could result in death or serious injury.

Operating Instructions

WCP85

370100-001  4/05

in the open po si tion and tag it to
prevent unexpected application of
power. Failure to do so could result in
fatal electrical shock!

3. Release all pressure within the

system before ser vic ing any
component.

4. Drain all liquids from the system

before servicing.

5. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.

6. Check hoses for weak and worn

condition before each use, making
certain that all connections are
secure.

7. Periodically inspect the pump and

system com po nents. Perform
routine maintenance as required
(See Maintenance Section).

8. Provide a means of pressure relief

for pumps whose discharge line can
be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean,

uncluttered and properly lighted; 

Condensate Unit

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2005 Wayne Water Systems

Specifications

Power supply requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz, 1 phase

Motor duty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intermittent

Liquid temperature range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°F to 125°F

Max. operating position  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

o

from vertical

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10” X 5” X  4-3/4”

Discharge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8"ID

Power cord  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6'  3 conductor with ground

Reservoir  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 quart plastic

For parts, product & service information

visit 

www.waynepumps.com

Summary of Contents for 370100-001

Page 1: ...rials Pump damage could occur if used in these applications and will void warranty Use for clear water application only Safety Guidelines This manual contains information that is very important to kno...

Page 2: ...11 This equipment is only for use on 120 volt single phase and is equipped with an approved 3 con ductor cord and 3 prong grounding type plug as shown in Figure 2 To reduce the risk of electric shock...

Page 3: ...event of pump failure Refer to Figure 7 for typical wiring diagram NOTE The alarm can be wired in the safety switch at the normally open NO contact TIPS FOR EASY INSTALLATION 1 After reading instruct...

Page 4: ...tact Maintenance Make certain that the pump is unplugged before attempting to service or remove any component This pump is assembled in the factory using special equipment therefore only authorized se...

Page 5: ...Refer to Maintenance section for cleaning instructions 1 Refer to Maintenance section for cleaning instructions 2 Measure from bottom of pump to highest point Rework discharge if height is greater tha...

Page 6: ...do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you Thi...

Page 7: ...OBLEMAS CON EL EQUIPO Para ayudarlo a reconocer esta informaci n observe los siguientes s mbolos Peligro indica una situaci n de riesgo inminente la cual si no se evita provocar la muerte o graves les...

Page 8: ...y la Ley de salud y seguridad ocupacional OSHA Riesgo de choque el ctrico Nunca conecte el cable verde o verde y amarillo a un terminal con corriente 11 Esta bomba es s lo para usar con 120 voltios m...

Page 9: ...a 6 en el punto m s alto de la l nea de descarga si no es posible hacer una pendiente continua hacia abajo Tenga cuidado de no doblar ni apretar el flujo de l quido condensado PASO 5 INSTALACI N DEL I...

Page 10: ...cablear en el interruptor de seguridad al contacto normalmente abierto NO 12 Despu s de la instalaci n pruebe la bomba para asegurarse de que el sistema funcione correctamente 13 Aseg rese de que la i...

Page 11: ...de limpieza 2 Mida desde la parte inferior de la bomba hasta el punto m s alto Ajuste la altura de la descarga si es mayor que 4 57 m 15 pies Consulte el Paso 4 de la Instalaci n para ver las instruc...

Page 12: ...S INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan l mites e...