background image

4

Operating Instructions and Parts Manual

6.  The motor is equipped with an 

automatic reset thermal protector.  

7.  While the pump is draining the 

pit, verify that the discharge 
piping is carrying the water to a 
point several feet away from the 
foundation.

8.  If pump discharge line is exposed to 

freezing temperature, the exposed 
line must be pitched to drain. 
Trapped water will freeze and 
damage the pump.

  Operation - Back-up Pump

 

 Always 

disconnect the power source 
before attempting to install, 
service, relocate or maintain 
the pump. Never touch sump pump, 
pump motor, water or discharge piping 
when pump is connected to electrical 
power. Never handle a pump or pump 
motor with wet hands or when standing 
on wet or damp surface or in water. 
Fatal electrical shock could occur.

 Risk 

of 

electrical shock! This pump 
is supplied with a grounding 
conductor and grounding 
type attachment plug. Use a grounded 
receptacle to reduce the risk of fatal 
electrical shock.
Never cut off the round grounding 
prong. Cutting the cord or plug will 
void the warranty and make the pump 
inoperable.

1.  Test Backup Pump operation by 

fi lling the sump with water while 
the main pump is unplugged.  
If the Backup Pump operates 
properly, plug the charger into 
the GFCI protected outlet to begin 
charging the battery.

2.  

 After installation, the standby 
pump will start when the water 
level rises above the depth that the 
primary pump should start.

3.  The control box has a DC charger 

designed to shorten the recharging 
time of your battery, and to prevent 
overcharging. In addition, the 
control box has a time delay which 
keeps the pump from repeated, 
short cycles when it shuts off. This 
time delay feature will allow the 
pump to run 20-25 seconds after the 
switch reaches the off position.

4.  The control box contains a multi-

colored indicator light. When AC 
power is present, the light will 
indicate the charging state, and 
not refl ect actual battery voltage, 
particularly with a defective 
battery. In order for the indicator 
light to provide an accurate 
reading, steps “a” through “d” 
must be followed.

a.  Unplug main AC pump and the 

charger--a power off alert tone 
will sound for 30 seconds.

b. Lift and release the fl oat switch 

to activate the standby pump.

c.  When the pump stops, read the 

test light:

 

 

Green:

 Indicates battery is  

 charged.

 

 

Yellow:

 Voltage is low,    

 

indicating battery is partially  

 charged.

 

 

Red:

 Battery is completely  

 

discharged or defective.

d. Plug in charger and main AC 

pump.

 

When AC power is out, and when 
pump has been running, the light 
will indicate battery status.

5.  A chirping sound from the control 

box will accompany the red light, 
indicating that the battery may 
require attention or replacement. 
Voltage is only an indicator of 
battery condition and may not 
refl ect the true condition of the 
battery. See Maintenance for 
instruction on assessing battery 
condition.

6.  A single thirty-second tone will 

sound when power to the system 
is interrupted. The unit will reset 
automatically when power is 
restored. A three-second tone will 
sound every time the pump starts.

  Maintenance - Primary Pump

 Always 

disconnect the power source 
before attempting to install, 
service, relocate or maintain 
the pump. Never touch sump pump, 
pump motor, water or discharge piping 
when pump is connected to electrical 
power. Never handle a pump or pump 
motor with wet hands or when standing 
on wet or damp surface or in water. 
Fatal electrical shock could occur.

1.  Let the pump cool for a minimum of 

two hours before servicing because 
the pump contains hot oil under 
pressure and the motor is hot.

2.  Disassembly of the motor prior to 

expiration of warranty will void the 
warranty. If repairs are required, 
see troubleshooting chart.

3.  Inlet should be kept clean and free 

of all foreign objects and inspect 
annually. A clogged inlet will 
damage pump.

4.  Pump should be checked monthly 

for proper operation. Pump can be 
checked for proper operation by 
briefl y removing pump power cord 
from the back of the water sensor 
plug and inserting directly into the 
grounded outlet. In this condition, 
the pump will run continuously. 
Once pump operation is verifi ed, 
replace pump power cord into the 
back of the water sensor plug.

5.  Wipe water sensor surface regularly 

to prevent silt or other coatings 
from building up on sensor face 
(see Figure 3).

Maintenance - Back-up Pump

 

 Always 

disconnect the power source 
before attempting to install, 
service, relocate or maintain 
the pump. Never touch sump 
pump, pump motor, water or discharge 
piping when pump is connected to 
electrical power. Never handle a pump 
or pump motor with wet hands or when 
standing on wet or damp surface or in 
water. Fatal electrical shock could occur.

1.  Once a month, check battery 

condition.

2.  Unplug the wall charger.

www.waynepumps.com

Figure 3

Working surface 
of sensor to be 
kept free of 
foreign material.

Operation - Primary Pump 
(continued)

Summary of Contents for 353501-001

Page 1: ...imary pump and an ESP25 backup pump Unpacking Inspect this unit before it is used Occasionally products are damaged during shipment If the pump or components are damaged return the unit to the place o...

Page 2: ...ain caustic chemicals and or foreign materials Pump damage may occur if used in these applications and will void warranty Back up Pump Battery Requirements 1 Use only a new fully charged 12 volt deep...

Page 3: ...equired see Figure 2 Risk of electrical shock This pump is supplied with a grounding conductor and grounding type attachment plug Use a grounded receptacle to reduce the risk of fatal electrical shock...

Page 4: ...cating battery is partially charged Red Battery is completely discharged or defective d Plug in charger and main AC pump When AC power is out and when pump has been running the light will indicate bat...

Page 5: ...ace switch Pump operates but delivers little or no water 1 Plugged impeller 2 Check valve installed backwards 3 Pump airlocked 4 Low line voltage 1 Clean out impeller 2 Reverse position of check valve...

Page 6: ...ery little or no water 1 Check valve missing or improperly installed 2 Obstruction in discharge pipe 3 Pump not rotated 30 4 Pump air locked 5 Discharge pipe length and or height exceeds capacity of p...

Page 7: ...Description Part Number Quantity Repair Parts List Figure 4 Primary Pump Model WSS10 4 3 2 6 1 5 For replacement parts or technical assistance call 1 800 237 0987 Please provide following information...

Page 8: ...sor 30037 001 1 Reference Number Description Part Number Quantity Repair Parts List Figure 5 Primary Pump Models WSS20 and WSS30 7 4 6 2 1 3 5 For replacement parts or technical assistance call 1 800...

Page 9: ...on and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A 1 Bracket 46049 001 1 2 Tee fitting 17233 002 1 3 Battery box 2321...

Page 10: ...217 001 1 Reference Number Description Part Number Quantity Repair Parts List Figure 7 Back up Pump Model WSS30 2 5 3 6 4 1 For replacement parts or technical assistance call 1 800 237 0987 Please pro...

Page 11: ...11 WSS10 WSS20 WSS30 www waynepumps com Service Record Date Maintenance performed Repair components required...

Page 12: ...URCHASE ON THE SYSTEM WSS20 THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on...

Page 13: ...rantie Joignez la ce manuel ou classez la dans un dossier pour plus de s curit Sp cifications WSS10 WSS20 WSS30 Exigences d alimentation de courant 120V 60 hz 12 V c c 120V 60 hz 12 V c c 120V 60 hz 1...

Page 14: ...ire lorsque vous manipulez la pile Un interrupteur pour prot ger contre un d faut de mise la terre DDFT est exig Cette pompe est con ue pour le pompage de l eau claire seulement Cette pompe n est pas...

Page 15: ...e la batterie la borne positive de la batterie Brancher le c ble noir la borne n gative Placer la couvercle sur la bo te de la batterie Si les c bles sont renvers s le dommage la bo te de contr le ou...

Page 16: ...tie et rendra la pompe inutilisable 1 Tester le fonctionnement de la pompe de secours en remplissant d eau le puisard au m me temps que la pompe principale est d branch e Si la pompe de secours travai...

Page 17: ...uisard le moteur de pompe la tuyauterie d eau ou de d charge lorsque la pompe est branch e au courant Ne jamais manipuler de pompe ou de moteur de pompe avec les mains humides ou debout dans l eau ou...

Page 18: ...suppl mentaire n endommagera pas la pompe Guide De D pannage Pompe de Secours Sympt me Cause s possible s Action corrective Pompe ne fonctionne pas 1 Raccords ne sont pas s rs 2 Batterie faible ou d f...

Page 19: ...Description et num ro de pi ce d apr s la liste de pi ces 1 Capteur d eau Switch Genius 30037 001 1 2 Kit d assemblage du moteur 60047 001 1 3 N cessaire de turbine 66011 001 1 4 Volute 28416 001 1 5...

Page 20: ...e si applicable Description et num ro de pi ce d apr s la liste de pi ces 1 N cessaire de couvercle sup rieur 60030 001 1 2 Stator 1 3 Support inf rieur Assem de Rotor 1 4 Plaque de turbine 15958 1 5...

Page 21: ...o de pi ce d apr s la liste de pi ces 1 Sangle 46049 001 1 2 Raccord en T 17233 002 1 3 Sangle pour batterie 23217 001 1 4 Chargeur 17220 004 1 5 Bo te de contr le 30209 002 1 6 Vis bo te de contr le...

Page 22: ...Num ro de Num ro R f rence Description de pi ce Quantit Liste de Pi ces D tach es Figure 7 Pompe de Secours Mod le WSS30 2 5 3 6 4 1 Pour des pi ces de rechange ou l assistance technique composer 1 80...

Page 23: ...WSS10 WSS20 WSS30 23 Fr Enregistrement d entretien Date Entretien ex cut l ments de remplacement requis...

Page 24: ...SYST ME WSS20 CECI EST LA REM DE EXCLUSIVE ET N IMPORTE QUELLE RESPONSABILIT POUR N IMPORTE QUEL ET TOUT DOMMAGES INDIRECTS OU D PENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas...

Page 25: ...a Adj ntela a este manual o arch vela en lugar seguro 25 Sp Especificaciones WSS10 WSS20 WSS30 Requisitos de suministro de energ a 120V 60 hz 12 V c c 120V 60 hz 12 V c c 120V 60 hz 12 V c c Motor Mo...

Page 26: ...a salada salmuera agua con detergentes o en ning n otro l quido que contenga qu micos causticos y o residuos y part culas sto le ocasionar a da os a la bomba y cancelar a la garant a Requisitos de la...

Page 27: ...dada 5 Coloque la caja de la bater a a unos 1 83 m del sumidero y de un tomacorrientes de 115 VCA El tomacorrientes debe tener un dispositivo autom tico contra cortocircuitos El rea debe estar limpia...

Page 28: ...ucir el riesgo de choque el ctrico mortal Nunca corte la clavija redonda de conexi n a tierra Si corta el cable o el enchufe se anular la garant a y har que la bomba no funcione 1 Verifique el funcion...

Page 29: ...gua para impedir que dep sitos de sedimento u otros materiales se acumulen en la superficie del sensor ver Figura 3 Mantenimiento Bomba de Respaldo Siempre desconecte el suministro de corriente antes...

Page 30: ...de diagn stico de aver as Bomba de Respaldo S ntoma Causa s Posible s Medida Correctiva La bomba no funciona 1 Conexiones flojas 2 Bater a baja o defectuosa 3 Interruptor de flotador atascado 4 Fusib...

Page 31: ...omo se muestra en la lista de repuestos 1 Sensor de agua Switch Genius 30037 001 1 2 Juego de ensamblaje del motor 60047 001 1 3 Juego de la propela 66011 001 1 4 Voluta 28416 001 1 5 Base 28418 001 1...

Page 32: ...puesto como se muestra en la lista de repuestos 1 Juego de cubierta superior 60030 001 1 2 Stator 1 3 Ensamble del rotor abrazadera inferior 1 4 Placa del impulsor 15958 1 5 Impulsor 60001 001 1 6 Vol...

Page 33: ...tos 1 M nsula 46049 001 1 2 Conexi n en T 17233 002 1 3 Compartimento de bater a 23217 001 1 4 Cargador 17220 004 1 5 Caja de control 30209 002 1 6 Tornillo caja de control 16119 002 4 7 Bomba 17218 0...

Page 34: ...ncia Descripci n de Parte Cantidad Lista de Partes de Reparaci n Figura 7 Bomba de Respaldo Modelo WSS30 Para piezas de repuestos o asistencia t cnica llame al 1 800 237 0987 S rvase proporcionar la s...

Page 35: ...WSS10 WSS20 WSS30 35 Sp Registro de Servicios Fecha Maintenimiento efectuado Componentes de reparaci n necesarios...

Page 36: ...5 A OS A PARTIR DE LA FECHA DE COMPRA PARA EL SISTEMA WSS20 ESTA ES LA UNICA GARANTIA Y CUALQUIER PERDIDA O RESPONSABILIDAD CIVIL SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algu...