background image

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Please read and save these instructions. Read carefully before
attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for
future reference.

Description

A sewage pump is intended for use in
domestic sewage lift stations. It is suitable
for pumping sewage, effluent, wastewater,
groundwater, and other nonexplosive,
noncorrosive liquids with up to 2 inch solids. 

An acceptable 
motor control

device must be provided at time of
installation.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols. 

Danger indicates 
an imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially

hazardous situation which, if not avoided,
could result in death or serious injury.

Operating Instructions and Parts Manual

Models DSP60 and DSP75

330600-001 6/03

Caution indicates a 
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates 

important

information, that if not followed, may
cause damage to equipment.

General Safety Information

1. Know the pump application, limitations,

and po ten tial hazards.

Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Use pump only with
liquids compatible with pump
component materials. Failure to follow
this warning can result in personal
injury and/or property damage.

2. Make certain that the power source

(electric motor) conforms to the
requirements of the equipment.

Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
in the open po si tion and
tag it to prevent unexpected

application of power. Failure to do so
could result in fatal electrical shock!

3. Release all pressure within the system

before ser vic ing any component.

4. Drain all liquids from the system before

servicing.

5. Secure the discharge line before starting

the pump. An unsecured discharge line
will whip, possibly causing personal
injury and/or property damage.

6. Check hoses for weak and worn

condition before each use, making
certain that all connections are secure.

7. Periodically inspect the pump and

system com po nents. Perform routine
maintenance as required (See
Maintenance Section).

8. Provide a means of pressure relief for

pumps whose discharge line can be shut-
off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when

working with pumps.

b. Keep work area clean, uncluttered

and properly lighted; replace all
unused tools and equipment.

c. Keep visitors a safe distance from the

work area. Make workshop child-
proof with pad locks, master switch es,
and by re mov ing starter keys.

10. When wiring an elec tri cal ly driven pump

such as this, fol low all electrical and safety
codes, as well as the most recent National
Electrical Code (NEC) and the Oc cu pa tion -
al Safety and Health Act (OSHA).

© 2003 Wayne Water Systems

Specifications

Power supply requirements.............120V, 60 hz

Circuit requirements ........................15 amps (min)

Motor duty .......................................Intermittent

Motor ................................................120V, 1 Phase

Horsepower  .....................................6/10 (DSP60), 3/4 (DSP75)

Motor full load .................................11.3A (DSP60), 11.8A (DSP75)

Liquid temperature range ...............40°F to 120°F

Max. operating position ..................45

o

from vertical

Dimensions .......................................14” x 12”

Intake ................................................2”

Discharge ..........................................2” NPT female

Power cord........................................16 gauge 3 conductor w/plug

Construction

Motor body material .......................Cold rolled steel
Motor housing .................................Cast iron
Volute ...............................................Cast iron
Impeller.............................................Cast iron
Seal plate ..........................................Cast iron
Shaft seal ..........................................Mechanical

GALLONS PER HOUR AT TOTAL HEAD IN FEET

Model

0’

5’

10’

15’

20’

25’

DSP60

8200

7500

6000

4000

2000

DSP75

8800

8160

7080

4920

2880

700

Performance

Sewage Pump

For parts, product & service information

visit 

www.waynepumps.com

Summary of Contents for 330600-001

Page 1: ...ow this warning can result in personal injury and or property damage 2 Make certain that the power source electric motor conforms to the requirements of the equipment Disconnect power before servicing If the power dis connect is out of sight lock in the open position and tag it to prevent unexpected application of power Failure to do so could result in fatal electrical shock 3 Release all pressure...

Page 2: ...lled in accordance with the NEC and local codes and ordinances 12 All wiring should be performed by a qualified electrician 13 Always connect this product to a grounded outlet equipped with a Ground Fault Circuit Interrupter GFCI device Consult a local electrician for installation and availability 2 Operating Instructions and Parts Manual Installation In any installation where property damage and ...

Page 3: ...l repair or replace at its option for the original purchaser any part or parts of its Pond Kit Sump Pumps or Water Pumps Product found upon examination by Wayne to be defective in materials or workmanship Please call Wayne 800 237 0987 for instructions or see your dealer Be prepared to provide the model and serial number when exercising this warranty All transportation charges on Products or parts...

Page 4: ...ke sure liquid level is adequate 1 Install check valve 2 Replace float switch 3 Remove and examine check valve for proper installation and free operation 4 Recheck all sizing calculations to determine proper pump size 1 Pump should not be used for water above 120 2 Replace or reposition pump Pump may start unexpectedly Disconnect power supply before servicing 3 If voltage is under recommended mini...

Page 5: ... S assurer que la source de puissance moteur électrique se conforme aux exigences de l équipement Débrancher la source de puissance avant de procéder au service Si la source d alimentation est hors vue la verrouiller dans la position ouverte et l étiquetter afin d éviter une application de puissance inattendue Manque de suivre ces directives peut résulter en secousse électrique 3 Dissiper toute la...

Page 6: ...n en métal mis à la terre c Autres moyens acceptables Remplacer les prises à deux broches avec des prises à trois broches mises à la terre correctement selon les codes et ordonnances locaux et de NEC 12 Toute installation de fils doit être performée par un électricien qualifié 13 Il est recommandé que le modèle soit branché dans un disjoncteur de fuite à la terre DDFT Consulter un électricien loca...

Page 7: ...Wayne Water Systems Wayne va réparer ou remplacer à sa discrétion pour l acheteur original toute pièce ou pièces du Kit D Étang de ces Pompes De Puisard ou Pompes À Eau Produit déterminées défectueuses par Wayne soit pour les matériaux ou la fabrication Veuillez appeler Wayne 800 237 0987 pour des instructions ou contacter votre marchand S assurer d avoir à sa disposition le numéro du modèle afin ...

Page 8: ...application 6 Clapet pris dans la position fermée ou installée à l envers 7 Soupape d arrêt fermée 1 L interrupteur de la pompe ne se met pas en marche sans que l eau recouvre le haut de la pompe 2 Si sauté remplacer avec un fusible de taille correcte ou réenclencher le disjoncteur 3 Si la tension est sous le minimum recommandé vérifier la taille des fils de l interrupteur général de la propriété ...

Page 9: ...ipo Desconecte el cordón eléctrico antes de darle servicio Si el tomacorrientes está fuera de su alcance apague la unidad con el interruptor y asegúrelo de modo que la unidad no pueda encenderse accidentalmente De no hacerlo podría morir electrocutado 3 Libere toda la presión del sistema antes de darle servicio a cualquier componente 4 Drene todos los líquidos del sistema antes de darle servicio 5...

Page 10: ...do a tierra correctamente b Conecte a tierra la unidad permanentemente usando un sistema metálico c Otros métodos adecuados Si el tomacorrientes disponible es de dos orificios debe reemplazarlo con un tomacorrientes de 3 orificios Debe seguir todos los códigos y ordenanzas locales para instalar el tomacorrientes 10 Sp Manual de Instrucciones y Lista de Repuestos que le asistan Desconecte la bomba ...

Page 11: ...una copia del recibo junto con el material o correspondencia Sírvase comunicarse con la compañía Wayne 800 237 0987 en EUA para recibir autorización e instrucciones para enviar el producto NO ENVIE ESTA GARANTIA A WAYNE Use este documento sólo para mantener sus records NO DEL MODELO _____________________ NO DE SERIE ________________________ FECHA DE INSTALACION __________________ ANEXE SU RECIBO A...

Page 12: ...ontrario 5 La bomba no es la adecuada para la aplicación en que se está usando 6 La válvula de chequeo está atascada o instalada incorrectamente 7 La válvula de cierre está cerrada 1 El interruptor no encenderá la bomba a menos que la bomba esté totalmente sumergida en agua 2 Si el fusible está quemado reemplácelo con uno adecuado o reconecte el cortacircuito 3 Si el voltaje es inferior al mínimo ...

Reviews: