Description

This pump is designed to sprinkle lawns
and small gardens from lakes, ponds, or
rivers, empty or fill stock tanks, remove
standing water from flooded areas,
transfer water or boost water pressure.
Flammable liquids such as gasoline,
chemicals or corrosive liquids should
never be used with this pump.

Safety Guidelines

This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols. 

Danger indicates 
an imminently haz-

ardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially haz-

ardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 
potentially haz-

ardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 

important infor-

mation, that if not followed, may cause
damage to equipment.

General Safety Information

1. Read these rules and

instructions carefully.
Failure to follow these
instuctions could
cause serious bodily
injury and/or property damage.

Operating Instructions and Parts Manual

PLS Series

This pump is non-
submersible. Keep

the motor dry at all times. Do not wash
the motor. Do not immerse. Protect the
motor from wet weather.

Do not allow any 
part of cord or

receptacle ends to sit in water or in
damp locations.

Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.   

This pump is not 
designed to handle

salt water, brine, laundry discharge or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will
void warranty.

All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local and national
codes.

2. Connect this product to a grounded

circuit equipped with a ground
fault circuit interruptor (GFCI)
device.

3. Before installing this product, have

the electrical circuit checked by an
electrician to ensure proper
grounding.

4. BE CERTAIN the pump

power source is dis-
connected before
installing or servicing
pump.

321602-001 1/06

5. Be sure the water source and piping

are clear of sand, dirt and scale.
Debris will clog pump and void war-
ranty.

6. Failure to protect pump and piping

from freezing could cause severe
damage and will void the warranty.

7. Do not run pump dry. 

Installation

PUMPING FROM LAKES, PONDS OR
SMALL STREAMS

1.  Locate pump as close as possible to

the water source, keeping the verti-
cal distance from the water to
pump as small as possible. Place
pump on level support. Protect
against flooding and excessive
moisture.

2. Long lengths of pipe or hose and

use of many fittings will reduce
pump flow. Use the smallest num-
ber of fittings and shortest possible
length of pipe or hose.

3. Be sure water is clear of debris such

as sand, mud, and gravel.

4. Connect inlet pipe or hose to pump.

The inlet connection is designed for
1" NPT thread. Rigid pipe such as
PVC will work fine for inlet and
outlet pipe. (Reminder: Minimize
length of pipe and number of fit-
tings.) An adapter for garden hose
is included (see Figure 1).

Figure 1

Pump Inlet

Pump Outlet

Portable Lawn
Sprinkler and
Utility Pump

Summary of Contents for 321602-001

Page 1: ...ons Pump only clear water Do not pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flamma ble and or explosive atmosphere Personal injury and or property dam ag...

Page 2: ...ncluded Figure 1 BOOSTING WATER PRESSURE Do not run pump with outlet pipe or nozzle closed The hose may burst from excessive pressure Use only reinforced high pressure hose or pipe for outlet pipe 1 C...

Page 3: ...or mud 1 Water level in well is lower than estimated 2 Steel piping if used is corroded or limed causing excess friction 3 Piping is too small in size 1 Be sure switch is on 2 Refer to instructions Ch...

Page 4: ...OSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL D...

Page 5: ...e autre application qui pourraient contenir des produits chi miques caustiques et ou des mati res trang res Des dommages la pompe pourraient d couler si utilis e dans ces applications et cela annulera...

Page 6: ...PVC ou un boyau de jardinage peut servir Un adapta teur pour le filetage du boyau de jardinage est inclus figure 1 RENFORCER LA PRESSION D EAU Ne pas faire fonc tionner la pompe avec un tuyau de sor t...

Page 7: ...rrod ou chaul provoquant une friction suppl mentaire 3 Le conduit est trop petit 1 S assurer que l interrupteur est en marche 2 Refer to instructions Check all connections 1 V rifier aupr s de la soci...

Page 8: ...ILIT ET D ADAPTATION UNE FONCTION PARTICULI RE SONT LIMIT ES UN AN COMPTER DE LA DATE D ACHAT CECI EST LE SEUL RECOURS EXCLUSIF ET TOUTE AUTRE RESPONSABILIT POUR TOUT AUTRE DOMMAGE QUELCONQUE INDIRECT...

Page 9: ...as inflamables o explosivas sto podr a ocasionarle heridas y o da os a su propiedad Esta bomba no est dise ada para bombear agua salada salmuera agua con detergentes o para ning n tipo de aplicaci n d...

Page 10: ...nexi n a tierra y un enchufe de uni n del tipo de cone xi n a tierra Use un recept cu lo con conexi n a tierra para reducir el riesgo de choque el ctrico mortal Nunca corte la pata redonda de conexi n...

Page 11: ...izadas ocasionando fricci n excesiva 3 Las tuber as son muy peque as 1 Cerci rese de que el interruptor est en ON encendido 2 Refer to instructions Check all wiring connections 1 Cons ltele a la compa...

Page 12: ...TEN OTRAS GARANTIAS EXPRESAS LAS GARANTIAS IMPLICITAS INCLUYENDO GARANTIAS EN RELACION AL MERCADEO O USOS ESPECIFICOS ESTAN LIMITADAS A UN A O A PARTIR DE LA FECHA DE COMPRA ESTA ES LA UNICA GARANTIA...

Reviews: