Making Measurements
Verify Instrument Operation

Before attempting to make a measurement, verify that the instrument is operational
and the battery is good. If the instrument is not operational, have it repaired before
attempting to make a measurement.

Range Selection

In addition to autoranging (Models 15XP and 35XP only) you can manually select
and lock a range by pressing the RANGE button. RANGE appears on the display to
indicate that manual ranging is active and the range is locked. When appropriate,
each subsequent press of the range button steps the meter to the next higher
range. When the highest range is reached the next press returns the meter to the
lowest range. To return to autoranging press the RANGE button. If RANGE still
shows on the display, autoranging is not available for the selected function. Use
autorange for all initial measurements. Then, when appropriate, use the RANGE
button to select and lock a range.

XW

Warning

To avoid electrical shock while manual ranging, use the display
annunciators to identify the actual range selected.

Correcting an Overload (

0o

 or 

-0o

) Indication 

W

An 

0o

 

or 

-0o

 indication may appear on the display to indicate that an overload

condition exists. For voltage and current measurements, an overload should be
immediately corrected by selecting a higher range. If the highest range setting does
not eliminate the overload, interrupt the measurement until the problem is identified
and eliminated. The 

0o

 indication is normal for some functions; for example,

resistance, continuity, and diode test.

Measuring DC Voltage

See Figure 

-1-

1.

 

Set the Function Switch to 

v

.

2.

 

Select the desired RANGE (5XP only).

3.

 

Connect the test leads: Red to 

E

, Black to 

COM.

4.

 

Connect the test probes to the circuit test points.

5.

 

Read the display, and, if necessary, correct any overload (

0o

) conditions.

Summary of Contents for XP Series

Page 1: ...ga ON L4Z 1X9 Tel 905 890 7600 Fax 905 89 6866 European Correspondence Address Meterman Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands Correspondence only no repair or replacement av...

Page 2: ...CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A 2A mA 400 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA 2A A 1832 400 5 6 4 2 1 35XP 3 Document Dimensions 3...

Page 3: ...ontinuity See Figure 6 5 Testing Diodes See Figure 7 5 Measuring Capacitance 35XP only See Figure 8 5 Measuring Temperature 35XP only See Figure 9 6 Measuring Frequency 35XP only See Figure 10 6 Measu...

Page 4: ...equipment etc where only smaller transient overvoltages may occur and not for primary supply lines overhead lines and cable systems Do not exceed the maximum overload limits per function see specifica...

Page 5: ...To return to autoranging press the RANGE button If RANGE still shows on the display autoranging is not available for the selected function Use autorange for all initial measurements Then when appropr...

Page 6: ...See Figure 3 1 Set the Function Switch to a current function A mA or A 2 Select the desired RANGE 5XP only 3 Connect the test leads Red to mA or A Black to COM 4 Turn off power to the circuit being m...

Page 7: ...rge any capacitors that may influence the reading 5 Connect the test probes across the resistance 6 Listen for the tone that indicates continuity 40 Testing Diodes See Figure 7 1 Set the Function Swit...

Page 8: ...t Voltage See Figure 11 1 Range switch may be set to OFF or any function range 2 Test leads are not used for the NCV test 3 Press the NCV button The display goes blank a tone sounds and the green LED...

Page 9: ...AX button for less than 1 second will put the meter into a mode of displaying the maximum or minimum readings Each time the button is pressed the meter will cycle to the next display mode Press the MI...

Page 10: ...5 A 1000V minimum interrupt rating 30 kA 6 3 x 32 mm Meterman FP300 WARRANTY The XP Series of Digital Multimeters are warranted against any defects of material or workmanship within a period of one 1...

Page 11: ...you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Meterman Test Tools Service Center see below for address Non Warranty Repairs and Repla...

Page 12: ...omagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Use...

Page 13: ...mA ranges 2 0 rdg 3 dgts on 2 A range AC CURRENT 45 Hz to 500 Hz Ranges 200 A 2000 A 20 mA 200 mA 2 A Accuracy 1 5 rdg 5 dgts on 200 A to 200 mA ranges 2 5 rdg 5 dgts on 2 A range RESISTANCE Ranges 2...

Page 14: ...30 dgts on 4 nF ranges 5 0 rdg 5 dgts on 40 nF and 400 F ranges 5 0 rdg 15 dgts on 4 mF range TEMPERATURE Ranges 20 C to 1000 C 4 F to 1832 F Accuracy 2 0 rdg 4 C 20 C to 10 C 1 0 rdg 3 C 10 C to 200...

Page 15: ...00 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON C...

Page 16: ...0 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CONTACT...

Page 17: ...0 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CO...

Page 18: ...0 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CO...

Page 19: ...17 10 1 3 2 2 4 K 1 9 3 4 5...

Page 20: ...A V V OFF 200 m 2m 20m 1 5V 9V 200 BATT 5XP 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE HOLD V HZ V auto off C OFF F mA A A 1832 400 11 1...

Page 21: ...19...

Page 22: ...ga ON L4Z 1X9 Tel 905 890 7600 Fax 905 89 6866 European Correspondence Address Meterman Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands Correspondence only no repair or replacement av...

Reviews: