Product Maintenance
Cleaning

To clean the meter, use a soft cloth moistened with water. To avoid damage to the
plastic components do not use benzene, alcohol, acetone, ether, paint thinner,
lacquer thinner, ketone or other solvents to clean the meter.

Troubleshooting

If the meter appears to operate improperly, check the following items first.
1.

 

Review the operating instructions to ensure the meter is being used properly.

2.

 

Inspect and test the continuity of the test leads.

3.

 

Make sure the battery is in good condition. The low battery symbol 

M

appears when the battery falls below the level where accuracy is guaranteed.
Replace a low-battery immediately.

4.

 

Check the condition of the fuses if the current ranges operate incorrectly.

Battery and Fuse Replacement

See Figure 

-14-

XW

WARNING

To avoid electrical, shock remove the test leads from both the
meter and the test circuit before accessing the battery or the
fuses.

To replace the fuse:
1.

 

Remove the 2 rear-case screws.

2.

 

Separate the case.

3.

 

Remove and replace the 2 A fuse (15XP or 35XP) or 0.315 fuse (5XP).

4.

 

Reassemble the meter.

Fuse:
Fast Blow 2 A/1000 V, minimum interrupt rating 30 kA (6 x 32 mm)
(Meterman FP200).
Fast Blow 0.315 A/1000V minimum interrupt rating 30 kA (6.3 x 32 mm)
(Meterman FP300)

WARRANTY

The XP Series of Digital Multimeters are warranted against any defects of material
or workmanship within a period of one (1) year following the date of purchase of
the multimeter by the original purchaser or original user. Any multimeter claimed to
be defective during the warranty period should be returned with proof of purchase
to an authorized Meterman Test Tools Service Center or to the local Meterman Test
Tools dealer or distributor where your multimeter was purchased. See Repair
section for details. Any implied warranties arising out of the sale of a Meterman
Test Tools multimeter, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited in duration to the
above stated one (1) year period. Meterman Test Tools shall not be liable for loss of
use of the multimeter or other incidental or consequential damages, expenses, or
economical loss or for any claim or claims for such damage, expenses or
economical loss. Some states do not allow limitations on how long implied
warranties last or the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.

Summary of Contents for XP Series

Page 1: ...ga ON L4Z 1X9 Tel 905 890 7600 Fax 905 89 6866 European Correspondence Address Meterman Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands Correspondence only no repair or replacement av...

Page 2: ...CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A 2A mA 400 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA 2A A 1832 400 5 6 4 2 1 35XP 3 Document Dimensions 3...

Page 3: ...ontinuity See Figure 6 5 Testing Diodes See Figure 7 5 Measuring Capacitance 35XP only See Figure 8 5 Measuring Temperature 35XP only See Figure 9 6 Measuring Frequency 35XP only See Figure 10 6 Measu...

Page 4: ...equipment etc where only smaller transient overvoltages may occur and not for primary supply lines overhead lines and cable systems Do not exceed the maximum overload limits per function see specifica...

Page 5: ...To return to autoranging press the RANGE button If RANGE still shows on the display autoranging is not available for the selected function Use autorange for all initial measurements Then when appropr...

Page 6: ...See Figure 3 1 Set the Function Switch to a current function A mA or A 2 Select the desired RANGE 5XP only 3 Connect the test leads Red to mA or A Black to COM 4 Turn off power to the circuit being m...

Page 7: ...rge any capacitors that may influence the reading 5 Connect the test probes across the resistance 6 Listen for the tone that indicates continuity 40 Testing Diodes See Figure 7 1 Set the Function Swit...

Page 8: ...t Voltage See Figure 11 1 Range switch may be set to OFF or any function range 2 Test leads are not used for the NCV test 3 Press the NCV button The display goes blank a tone sounds and the green LED...

Page 9: ...AX button for less than 1 second will put the meter into a mode of displaying the maximum or minimum readings Each time the button is pressed the meter will cycle to the next display mode Press the MI...

Page 10: ...5 A 1000V minimum interrupt rating 30 kA 6 3 x 32 mm Meterman FP300 WARRANTY The XP Series of Digital Multimeters are warranted against any defects of material or workmanship within a period of one 1...

Page 11: ...you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Meterman Test Tools Service Center see below for address Non Warranty Repairs and Repla...

Page 12: ...omagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Use...

Page 13: ...mA ranges 2 0 rdg 3 dgts on 2 A range AC CURRENT 45 Hz to 500 Hz Ranges 200 A 2000 A 20 mA 200 mA 2 A Accuracy 1 5 rdg 5 dgts on 200 A to 200 mA ranges 2 5 rdg 5 dgts on 2 A range RESISTANCE Ranges 2...

Page 14: ...30 dgts on 4 nF ranges 5 0 rdg 5 dgts on 40 nF and 400 F ranges 5 0 rdg 15 dgts on 4 mF range TEMPERATURE Ranges 20 C to 1000 C 4 F to 1832 F Accuracy 2 0 rdg 4 C 20 C to 10 C 1 0 rdg 3 C 10 C to 200...

Page 15: ...00 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON C...

Page 16: ...0 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CONTACT...

Page 17: ...0 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CO...

Page 18: ...0 1000 A A 35XP RANGE NON CONTACT VOLTAGE HOLD V HZ V auto off C OFF F mA A A 1832 400 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE NON CO...

Page 19: ...17 10 1 3 2 2 4 K 1 9 3 4 5...

Page 20: ...A V V OFF 200 m 2m 20m 1 5V 9V 200 BATT 5XP 2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA 2A A mA 400 1000 A A 35XP RANGE HOLD V HZ V auto off C OFF F mA A A 1832 400 11 1...

Page 21: ...19...

Page 22: ...ga ON L4Z 1X9 Tel 905 890 7600 Fax 905 89 6866 European Correspondence Address Meterman Test Tools Europe P O Box 1186 5602 BD Eindhoven The Netherlands Correspondence only no repair or replacement av...

Reviews: