AC Current
Range
Resolution Accuracy
Overload Prot.
Freq. Response
400A
0.1A
±(2%rdg + 5dgt)
800A
40-450Hz
600A
1A
±(2%rdg + 5dgt)
800A
40-450Hz
DC Voltage
Range
Resolution Accuracy
Input Imped. Overload Prot.
600V
1V
±(0.75%rdg + 2dgt) 10M
Ω
1000VDC/750VAC
AC Voltage
– Frequency response: 40-450Hz
Range
Resolution Accuracy
Input Imped. Overload Prot.
400V
0.1V
±(1.2%rdg + 5dgt) 10M
Ω
1000VDC/750VAC
600V
1V
±(1.2%rdg + 5dgt) 10M
Ω
1000VDC/750VAC
Frequency (Hz)
– Autoranging for current and voltage
Range
Resolution Accuracy
Sensitivity
Overload Prot.
4KHz
0.001Hz
±(0.5%rdg + 5dgt) 5A/1V
660Vrms/800A
20KHz
0.01Hz
±(0.5%rdg + 5dgt) 5A/5V
660Vrms/800A
Resistance
Range
Resolution Accuracy
Open circ.volts Overload Prot.
4K
Ω
1
Ω
±(1%rdg + 5dgt)
0.5VDC
660Vrms
Diode Test
Range
Resolution Accuracy
Open circ.volts Overload Prot.
0.001V
±(1%rdg + 2dgt)
3.2VDC max
660Vrms
Max short circuit current: 0.8mA (typical)
Audible Continuity Test
Range
Threshold
Open circ.volts
Overload Prot.
40
Ω
±15
Ω
3.2VDC max
660Vrms
Max short circuit current: 0.8mA (typical)
Peak Hold Measurement, AC Voltage
Range
Resolution Accuracy
Input Imped. Overload Prot.
400V
0.1V
±(1.5%rdg +10dgt) 10M
Ω
1000VDC/750VAC
600V
1V
±(1.5%rdg +10dgt) 10M
Ω
1000VDC/750VAC
Frequency response: 40-450Hz
Peak Hold Measurement, AC Current
Range
Resolution Accuracy
Overload Prot. Freq. Response
400A
0.1A
±(2%rdg +10dgt)
800A
40-450Hz
600A
1A
±(2%rdg +10dgt)
800A
40-450Hz
D • Spezifikationen
Allgemeine Spezifikationen
Anzeige: 3 3/4-stelliges LCD, max Ablesung 3999. Funktions- und
Einheitsanzeigen
Überlastanzeige : “OL”.
Polaritätsanzeige: automatisch; positiv unterstellt; negativ angezeigt.
Nullabgleich: automatisch für alle Funktionen und Bereiche, ausg. Gleichstrom
(Nullabgleichtaste).
– 16 –
AC68.Man.07.00 11/30/00 6:50 PM Page 18