ENVIRONMENTAL
Noise Cl o c k Frequency
Switch selectable noise frequencies are listed
Clock Frequency
160 Hz
1.6 kHz
16 kHz
160 kHz
1.6 MHz
Analog Noise
Bandwidth
10
Hz
100
Hz
1 kHz
10 kHz
100 kHz
OPERATIONAL MODES
FUNC
Function Mode - Provides the selected
form at the main output.
S/N Signal-to-Noise operation adds noise to a selected
signal of constant amplitude. The signal-to-noise ratio
is variable from 0 to +60 dB.
N/S Noise-to-Signal operation adds a selected signal
to a constant amplitude noise. The noise-to-signal ratio
is variable from
0
to
+60 dB.
FM Frequency Modulation - Provides random modu-
lation of the frequency of the generator. The S/N
- N/S
(dB)
ratio control also controls the amount of fre-
quency deviation.
NOTE
When noise is added to the signal output,
specifications apply up to 200 kHz and
the square wave rise time is dera ted by
a factor of 10. In the clock range of
1.6 MHz, the maximum calibrated signal-
to-noise ratio is 30 d B
Temperature
All specifications listed, except stability, are for
For operation from O°C to
derate all
specifications by factor of 2.
MECHANICAL
Dimensions
inches wide,
inches high,
inches deep
Weight
8 Ibs net, 12 Ibs shipping
Power
105 V to 125 V or 200 V to
250
V,
50
Hz to
400
Hz.
Less than 15 watts.
NOTE
All specifications apply for frequencies
obtained when dial is between 0. 1 and
2.0 and at
V p-p in to a 50 ohm load.
It is possible to stop the generator from
oscillating by applying a negative VCG
voltage when the dial is already set at
minimum frequency. VCG inputs up to
30 V will not permanently damage the
ins trumen t.