Wavetek 132 Manual Download Page 4

V E R S A T I L I T Y

HORIZONTAL PRECISION

Waveforms

Sine

,

square

,

triangle

waveforms

and analog noise

,

or

digital noise l-u--L

Frequency Range of Signal

0.2 Hz to 2 MHz in 6 decade ranges

Ranges
x 10

X l 00

X1K

X 1 0 K

XIOOK

X1M

0.2 Hz to 20 Hz

2 Hz to 200 Hz

20 Hz to 2 kHz

200 Hz to 20 kHz

2 kHz  to 200 kHz

20 kHz  to 2 MHz

Function Outputs

Sine

,

 square

,

 and triangle

selectable,

with 60 d B step attenuator in 10 d B steps and over-

lapping calibrated vernier; 5Oa output impedance,

20 V p-p into open circuit and 10 V p-p into

load from 

 source impedance.

Sync Output

Greater than 1 V p-p square wave into open circuit at

 output impedance.

DC Offset

 V offset

 V offset into

 load) controlled

from rear panel; peak amplitude limited by the dynam-

ic range of the amplifier output.

VCG - Voltage Controlled Generator

Frequency of the generator may be dc-programmed,

or ac-modulated by external 0 to

V signal. Voltage

control circuitry is capable of 1000: 1 deviation. The

VCG amplifier has a 100 k H z bandwidth and a slew

rate of 0.1

 The instantaneous frequency is the

result of the sum of the dial setting and the externally

applied voltage.

Stability

Short term

for 10 minutes

Long term

 for 24 hours

Percentages apply to amplitude, frequency, and dc

offset.

SECTIO N

1

SPECIFICATIONS

Dial Accuracy

 of full scale, 1 Hz to 2 MHz

Frequency Vernier

One

turn equals 1% of full scale.

Time Symmetry

% through XIOOK range

VERTICAL PRECISION

Sine Wave Frequency Response

Amplitude change with frequency less than:

0.1 d B from 0.2 Hz to 200 k H z

0.5 d B from 0.2 Hz to 2 MHz

PURITY

Sine Wave Distortion

Less than:

0.5% on X10, X100, X1K,X 1 0 K ranges

1.0% on XIOOK range

All harmonics 30 d B down on Xl MHz range

Square Wave Rise and Fall Time

Less than 50 ns terminated into 

NOISE

outputs

Pseudo-random analog or digital noise wit

h

a maximum

of 20 V p-p excursion (open circuit) with 60 d B step

attenuator in 10

dB steps and overlapping calibrated

vernier.

Sequence Lengths

Push buttons on the front panel provide a sequence

length of

- 1, 

- 1, or

- 1.

1

Summary of Contents for 132

Page 1: ...INSTRUMENT OPERATION AND MAINTENANCE THE INFORMATION IN THIS DOCUMENT MAY NOT BE DUPLICATED IN ANY MANNER WITHOUT THE PRIOR APPROVAL IN WRITING OF WAVETEK SAN DIEGO 9045 Balboa Ave San Diego CA 92123...

Page 2: ...s can be used program ensures that the latest electronic developments individually or combined to provide selectable cali are incorporated into the Wavetek instruments by the brated signal to noise an...

Page 3: ...strument comply with installation instructions MAINT ENANCE may requir e power on w i th th e instrumen t cover sremoved shoul d be don eonly by qualified personne l awar eof the elect h a zards WARNI...

Page 4: ...circuitry is capable of 1000 1 deviation The VCG amplifier has a 100 kHz bandwidth and a slew rate of 0 1 The instantaneous frequency is the result of the sum of the dial setting and the externally a...

Page 5: ...he amount of fre quency deviation NOTE When noise is added to the signal output specifications apply up to 200 kHz and the square wave rise time is dera ted by a factor of 10 In the clock range of 1 6...

Page 6: ...UNC push button Connect oscilloscope to the OUT connec tor with a terminator Set frequency dial to the 1 0 mark and FREQ VERNIER to CAL position Set function selector to the position Set OUTPUT ATTEN...

Page 7: ...nd noise generators This control has no affect on the noise frequency 2 FREQ VERNIER Allows precision electronic control of the signal output frequency A full turn of the control is approximately equa...

Page 8: ...pen circuit providing 20 V peak to peak maxi mum or into a load providing a 10 V peak to peak output OUTPUT ATTEN dB Attenuates the output both signal and noise from 0 dB to 60 dB in six calibrated 10...

Page 9: ...he value to the right of the detent mark VCG IN This connector allows external volt age control of function generator frequency Up to 1000 1 frequency change may be obtained A positive voltage increas...

Page 10: ...termination Select the desired waveform by setting function 1 2 3 4 5 Terminate OUT connector with 50 ohm 2 watt termination Select the desired waveform by setting function selector to or Set FREQ HZ...

Page 11: ...rce 1 Select the desired signal waveform by setting function selector to or 2 Set frequency dial and FREQ HZ range multi plier for desired signal output frequency 3 Depress MODE S N push button 4 Sele...

Page 12: ...t output signal amplitude by setting OUT PUT ATTEN dB control to appropriate atten uation position and fine adjusting signal to de sired amplitude with OUTPUT VERNIER dB control Operation as a Digital...

Page 13: ...lt use Converting a 115 volt unit for 230 volt operation is a simple matter 2 Loosen two captive thumb screws on rear panel and remove panel 1 Remove power cord 3 4 The conversion switch is located on...

Page 14: ...hes function like a Schmitt trigger with the limit points set at the wave form extremes firing when the triangle wave reaches 1 25 volts and 1 25 volts When firing occurs the hysteresis and output swi...

Page 15: ...is considerably less in amplitude than the triangle wave input and is thus amplified to be equal to the triangle wave Either square triangle or sine waveforms can be se lected as a signal source The n...