APCD-LM043-4.0
159
Appendix B
Factory Configuration
This appendix identifies the factory configuration settings for the CCU and EUM.
Table 42
CCU Factory Configuration
Parameter
Default Configuration
Console Prompt
The default console prompt is the station
(CCU) ID.
Deregistration Count
8
DHCP Relay
Disabled
Ethernet IP Address
192.168.10.250
Ethernet Netmask
24
Gateway IP Address
192.168.10.1
GOS Definitions
BE (0 - 384 kbps)
Bronze (0 - 1024 kbps)
Silver (128 - 256 kbps)
Gold (256 - 512 kbps)
Denied (0 kbps)
Note: The above data rates are based on
FTP transfers from a single EUM, using
maximum-sized packets)
GOS Default (Authorization Table)
BE (Best Effort)
Maximum Associations
75
Password
<cr>
Port Filters
137 (both)
138 (both)
139 (both)
1512 (both)
Radio Frequency
9050 (905.0MHz)
Summary of Contents for LMS4000
Page 1: ...LMS4000 900 MHz Radio Network User Guide APCD LM043 4 0...
Page 14: ...This page is intentionally left blank...
Page 22: ...This page is intentionally left blank...
Page 76: ...This page is intentionally left blank...
Page 90: ...This page is intentionally left blank...
Page 114: ...This page is intentionally left blank...
Page 142: ...This page is intentionally left blank...
Page 172: ...This page is intentionally left blank...
Page 180: ...This page is intentionally left blank...
Page 198: ...This page is intentionally left blank...
Page 240: ...This page is intentionally left blank...
Page 270: ...This page is intentionally left blank...
Page 278: ...This page is intentionally left blank...