37
TnP Prime
User Manual
Wavecom
Dump mode
Printer will enter dump mode after printing printer configuration. In the dump mode, all characters will be
printed in 2 columns as following. The left side characters are received from your system and right side data
are the corresponding hexadecimal value of the characters. It allows users or engineers to verify and debug the
program. Dump mode requires 2” wide paper width.
Note:
1. Turn off / on the power to resume printer for normal printing.
2. Press FEED button to go back to the previous menu.
Printer Initialization
Printer initialization is used to clear DRAM and restore printer settings to defaults. Printer initialization is
activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green after 5 amber flashes. (Any green will do during the 5 flashes).
• The LED colour will be changed as following:
1. Amber
2. Red (5 flashes)
3. Amber (5 flashes)
4. Green (5 flashes)
5. Green/amber (5 flashes)
6. Red/amber (5 flashes)
7. Solid green
Printer configuration will be restored to defaults as below after initialisation.
Parameter
Default setting
Parameter
Default setting
Speed
127 mm/sec (5 ips) (203DPI) 76.2
mm/sec (3 ips) (300DPI)
Tear Mode
On
Density
8
Peel off Mode
Off
Label Dimensions
2” (50.8 mm) x 2” (50.8 mm)
Cutter Mode
Off
Sensor Type
Gap sensor
Serial Port Settings
9600 bps, none parity, 8 data
bits, 1 stop bit
Gap Setting
0.12” (3.0 mm)
Code Page
850
Print Direction
0
Country Code
001
Reference Point
0,0 (top left corner)
Clear Flash Memory
No
Offset
0
IP Address
DHCP