Test Case
Test Summary
Ref Standard
Thermal Shock Test
Temp (low) : min storage
Temp (high) : max storage
6 min dwell at each extreme
0.5 to 3 min transition
Duration: 30 cycles (Group 2,3)
IEC 60068-2-14
Moist Heat Cyclic Test
Temp (low) : nominal ambient
Temp (high) : max operating
Humidity (high) : 95% ±5% RH
9 hr dwell at each temperature
3 hr transition between temps
Duration: 6 cycles x 24 hours
(144 hrs total)
IEC 60068-2-30
Operational Durability
SIM insertion : 500 cycles
System
connector
:
10,000
cycles
RF connector : 5,000
1/52 41-FEA 202 8370
Free Fall Test
1m drop height on to concrete
-
all sides
-
all faces
-
all corners
-
any extended features
IEC 60068-2-32 Test Ed