background image

Installation Instructions

Please read all instructions before installing

DESCRIPTION AND OPERATION

The RT-50 is a time switch that turns OFF the connected light or fan when the 

selected time expires. The light behind the ON/OFF button illuminates while the 

switch is OFF. One of the time button indicators is always lit to indicate the last 

used timer.

Manual ON

Turn ON the connected light or fan by pressing the desired time button, or the 

ON/OFF button. If you press the ON/OFF button, it activates the timer that was 

last used.

Manual OFF

While a timer is active, you can press the ON/OFF button to turn OFF the 

connected light or fan without delay. 

Changing the selected time

If you decide that you need more or less time than you originally selected, restart 

the time switch by pressing the button that matches the amount of time you think 

you’ll need.

RT- 50

Time Switch

7- Button Preset

   

SPECIFICATIONS

Voltage  ....................................................................... 120VAC, 60HZ

Load (Single Pole Circuit)

  Incandescent or fluorescent lamp  ...........................0 – 600 Watt

  Fan Motor ............................................................................1/6HP

Time Delay...............................................1, 5, 10, 20, 30, 60 minutes

Environment ..............................................................Indoor use only

Operating Temperature ..............................32° to 131°F (0° to 55°C)

Humidity ....................................................95% RH, non-condensing

Tools Needed

  Insulated Screwdriver

  Wire Strippers

Call 800.879.8585 for Technical Support

Santa Clara, CA 95050

Summary of Contents for RT-50

Page 1: ... Manual OFF While a timer is active you can press the ON OFF button to turn OFF the connected light or fan without delay Changing the selected time If you decide that you need more or less time than you originally selected restart the time switch by pressing the button that matches the amount of time you think you ll need RT 50 Time Switch 7 Button Preset SPECIFICATIONS Voltage 120VAC 60HZ Load Si...

Page 2: ...hey can be identified later Disconnect the wires Make sure the insulation is stripped off the wires to expose their copper cores to the length indicated by the Strip Gage in Fig 2 approximately 1 2 inch 4 Wire the time switch Twist the existing wires together with the wire leads on the time switch as indicated in the drawing Cap them securely using the wire nuts provided See Fig 3 Connect the gree...

Page 3: ...k the light bulb and or motor switch on the fan mechanism Make certain that the circuit breaker is ON and functioning Turn OFF power to the circuit then check wire connections Call 1 888 817 0571 for technical support Light or fan will not turn OFF Press the ON OFF button If connected light or fan does not turn OFF turn OFF power to the circuit then check wire connections COVER PLATES WattStopper ...

Page 4: ...tivo usted puede oprimir el botón de Encendido Apagado para apagar sin retardo la lámpara o ventilador conectado Cambio del tiempo seleccionado Si usted decide que necesita más o menos tiempo con respecto al tiempo seleccionado originalmente reinicie el interruptor temporizado oprimiendo el botón de selección de Retardo de Apagado que coincide con la cantidad de tiempo que usted cree que se necesi...

Page 5: ...onecte los alambres Asegúrese de remover el aislamiento de los alambres para exponer sus núcleos de cobre según la longitud indicada en la Figura 3 aproximadamente 1 2 pulg 4 Cablee el interruptor temporizado Empalme retorciendo los alambres existentes con los alambres del interruptor temporizado según se indica en el diagrama Fíjelos de manera firme utilizando los conectores wire nuts para alambr...

Page 6: ...cadora de Retardo de Apagado Haga sombra sobre el interruptor para asegurarse que ninguna de las luces indicadoras del interruptor esté encendida Revise la bombilla y o el interruptor del motor en el mecanismo del ventilador Verifique que el cortacircuitos breaker esté encendido y funcionando Apague el suministro eléctrico hacia el circuito luego revise las conexiones de los alambres Llame al telé...

Reviews: