•   The time delay can be set from 15 seconds to 30 minutes. Check the time 

delay setting for each RD‑250 in your multi‑way configuration. Ensure that all 

RD‑250s have the same time delay setting. Ensure that there is no movement 

within any of the sensors’ view for the set time period. Hot air currents and 

heat radiant devices can cause false detection. Make sure the sensor is at least 

6 feet (2 meters) away from devices that are a significant heat source (e.g., 

heater, heater vent, high wattage light bulb).

If load does not respond properly after following troubleshooting, turn OFF 

power to the circuit then check wire connections or call technical support.

COVER PLATES

WattStopper RD wall switches fit behind industry standard decorator style switch 

cover plates.

WARRANTY INFORMATION

WattStopper warranties its products to be free of defects in materials 

and workmanship for a period of five (5) years. There are no obligations 

or liabilities on the part of WattStopper for consequential damages 

arising out of, or in connection with, the use or performance of this 

product or other indirect damages with respect to loss of property, 

revenue or profit, or cost of removal, installation or reinstallation.

Please 

Recycle

2800 De La Cruz Boulevard, Santa Clara, CA 95050

Technic

al Support: 800.879.8585 • www.watt

stopper.com

2800 De La Cruz Boulevard, Santa Clara, CA 95050 

800.879.8585 • www.wattstopper.com 

08703r3 3/2013

Please 

Recycle

Summary of Contents for RD‑250

Page 1: ... the dimmable load ON the RD 250 recalls the last used dimming level While the sensor is factory preset as a Vacancy Sensor with manual ON operation it can be adjusted to work as an Occupancy Sensor that turns the controlled load ON automatically upon detection of occupancy in the area The RD 250 can be wired with up to 3 additional RD 250s for multi way Manual Auto ON OFF of one or several loads ...

Page 2: ...F DIM button can be used to manually turn ON and OFF the lighting load and to dim it UP and DOWN To turn the load ON tap firmly on the ON OFF DIM button once The amber LED turns OFF and the load turns ON to the last used dimming level The lighting load may or may not appear to be ON depending on how low the lights were set the last time they were dimmed Once the load has been turned ON push and ho...

Page 3: ...ted to the existing switch so that they can be identified later Disconnect the wires Make sure the insulation is stripped off of the wires to expose their copper cores to the length indicated by the Strip Gage in Fig 3 approx 1 2 inch For your safety Connecting a proper ground to the sensor provides protection against electrical shock in the event of certain fault conditions If a proper ground is ...

Page 4: ... the auxiliary RD 250 and to the TRAVELER 1 wire Connect the TRAVELER 1 wire from the black wire of the auxiliary RD 250 to the black wire of the master RD 250 Connect the lamp power LOAD to the red wire on the master RD 250 Cap the red wire on the auxiliary RD 250 Connect the TRAVELER 2 wire coming from the yellow wire of another RD 250 to the yellow wire of the RD 250 that you are wiring AUXILIA...

Page 5: ...em with the lens positioned above the ON OFF DIM button lens at top ON OFF DIM button at bottom Secure to the wall box with the screws provided 6 Make any necessary adjustments See the SENSOR ADJUSTMENT PROGRAMMING section for information 7 Install cover plate Install industry standard decorator wall switch cover plate not included 8 Restore power to the circuit Turn on the breaker or replace the ...

Page 6: ...level at maximum fully clockwise The light level must be adjusted when lights would normally be turned OFF because there is enough natural illumination Each RD 250 may have a different light level setting 1 Set all RD 250s to Mode 1 Manual ON except for the one that you re adjusting Set the RD 250 you re adjusting so that it is in Mode 2 Automatic ON 2 Reduce the time delay to 15 seconds 3 Adjust ...

Page 7: ...s maximum TROUBLESHOOTING Check the position of the Air Gap Switch on all RD 250s before beginning troubleshooting Lighted switch is OFF no load response to ON OFF DIM button s press or to any of the RH 253 momentary wall switches if applicable Make certain that the circuit breaker is on and functioning Lighted switch is ON no load response to ON OFF DIM button s press or to any of the RH 253 mome...

Page 8: ...roubleshooting turn OFF power to the circuit then check wire connections or call technical support COVER PLATES WattStopper RD wall switches fit behind industry standard decorator style switch cover plates WARRANTY INFORMATION WattStopper warranties its products to be free of defects in materials and workmanship for a period of five 5 years There are no obligations or liabilities on the part of Wa...

Reviews: