TS-400-24

InteliSwitch® Digital Time Switch

24VDC/VAC 

SPECIFICATIONS

 Voltages  . . . . . . . . . . . . . . . . . . . . . . .

 24VAC, 24VDC, VAC Half Rectified

  Current Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . Max. 15mA DC
              . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max. 15mA AC

 Outputs

   

Isolated Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A/30V SPDT

   

Pulse On/Off:

   

         Width. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150ms

                    Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5A
  Time-Out Adjustment

. . . . . . . . . . . . . . . . . . . . . .

 5 minutes to 12 hours

  Time-Out Override

  . . . . . . . . . . . . . . .

0 to 1 hour in 5 minute increments

     . . . . . . . . . . . . . . . . . . .

1 hour to 12 hours in 15 minute increments

  Operating Temperature

. . . . . . . . . . . . . . . . . . .

32° to 104°F (0° to 40°C)

  Humidity

 . . . . . . . . . . . . . . . . . . . . . . . . . 

Rh 5% to 95%, non-condensing

Ins
tallation Ins

tructions

U.S. Patent: 5,640,113

Summary of Contents for intelliswitch TS-400-24

Page 1: ... 15mA AC Outputs Isolated Relay 1A 30V SPDT Pulse On Off Width 150ms Current 1 5A Time Out Adjustment 5 minutes to 12 hours Time Out Override 0 to 1 hour in 5 minute increments 1 hour to 12 hours in 15 minute increments Operating Temperature 32 to 104 F 0 to 40 C Humidity Rh 5 to 95 non condensing Installation Instructions U S Patent 5 640 113 ...

Page 2: ...om a longer time to a shorter time scroll down or increase from a shorter time to a longer time scroll up To choose the scrolling direction consider the time out DELAY setting and then whether the usual temporary need will be for more or less time Override Operation Holding the ON OFF button for longer than 4 seconds causes the timer to scroll through time increments starting from the time out DEL...

Page 3: ... Push the ON OFF switch to activate the lights The timer begins its countdown Push the ON OFF switch during countdown to turn the lights off 5 Select feature settings using the Switch Adjustment procedures 6 Install cover plate WIRING DIAGRAMS WA 200 exploded CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING WARNING BE SURE THE GROUND WIRE IS SECURELY CONNECTED 24V IN PULSE OFF PULSE...

Page 4: ...s it restarts the selection scrolling at 5 minutes Scroll UP or down dn To have the user s time override options decrease from a longer time to a shorter time set Scroll for dn down To increase from a shorter time to a longer time set Scroll for UP FLASH ON or OFF Sound ON or OFF When the setting selection is complete the unit will either Beep once and display END if the calibration button is bein...

Page 5: ... the unit is operating properly set the time out period to minimum Lights should turn off after five minutes 3 If lights still do not turn off call 800 879 8585 for technical support Re adjusting the Time out Period To re adjust the time out period set the new time delay in the user settings If this is done while the timer is counting down a prior setting the new setting will not be recognized unt...

Page 6: ...N WARRANTY INFORMATION WattStopper warranties its products to be free of defects in materials and workmanship for a period of five years There are no obligations or liabilities on the part of WattStopper for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of remova...

Reviews: