background image

SWITCH ADJUSTMENT

Enter Settings Mode by pressing the Calibration Button 
(located on the left, behind the faceplate). 

•   If no input occurs within four seconds the display 

flashes then moves to the next setting.

•  Press the Calibration Button to view the settings 

without making changes. 

•  Press the 

ON

/

OFF

 button within four seconds to 

change the setting.

DELAY: 

5 min. to 12 hr.

DELAY sets the time-out period. The selections begin at 
the currently set time (3 hours, default). When the time is 
less than an hour, the time increases by 5 minutes each 
time you press the ON/OFF button. When the time is more than an hour, 
it increases by 15 minues. When the selection passes 12 hours, it 
restarts the selection scrolling at 5 minutes.

Scroll: 

UP or down (dn)

To have the user’s time override options decrease from a longer time to a shorter time, set 

Scroll for 

dn

 (down). To increase from a shorter time to a longer time, set Scroll for 

UP

FLASH: 

ON or OFF

Sound: 

ON or OFF

When the setting selection is complete the unit will either:
•   Beep once and display END if the calibration button is being held; release the button to 

continue.

•   Beep three times while it displays END. This gives you a chance to press the 

ON

/

OFF

 

button to restart the setting procedure. 

If you don’t press either button within three seconds, the unit exits the Settings Mode and 
resumes its previous state.

ON

1

TS-400-24

LCD Display

Call 800.879.8585 for Technical Support

WIRING

ON/OFF 

Button

Calibration 

Button

#16-#18

Insert wires as 

shown and tighten 

screw in the clock-

wise direction.

Summary of Contents for intelliswitch TS-400-24

Page 1: ... 15mA AC Outputs Isolated Relay 1A 30V SPDT Pulse On Off Width 150ms Current 1 5A Time Out Adjustment 5 minutes to 12 hours Time Out Override 0 to 1 hour in 5 minute increments 1 hour to 12 hours in 15 minute increments Operating Temperature 32 to 104 F 0 to 40 C Humidity Rh 5 to 95 non condensing Installation Instructions U S Patent 5 640 113 ...

Page 2: ...om a longer time to a shorter time scroll down or increase from a shorter time to a longer time scroll up To choose the scrolling direction consider the time out DELAY setting and then whether the usual temporary need will be for more or less time Override Operation Holding the ON OFF button for longer than 4 seconds causes the timer to scroll through time increments starting from the time out DEL...

Page 3: ... Push the ON OFF switch to activate the lights The timer begins its countdown Push the ON OFF switch during countdown to turn the lights off 5 Select feature settings using the Switch Adjustment procedures 6 Install cover plate WIRING DIAGRAMS WA 200 exploded CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING WARNING BE SURE THE GROUND WIRE IS SECURELY CONNECTED 24V IN PULSE OFF PULSE...

Page 4: ...s it restarts the selection scrolling at 5 minutes Scroll UP or down dn To have the user s time override options decrease from a longer time to a shorter time set Scroll for dn down To increase from a shorter time to a longer time set Scroll for UP FLASH ON or OFF Sound ON or OFF When the setting selection is complete the unit will either Beep once and display END if the calibration button is bein...

Page 5: ... the unit is operating properly set the time out period to minimum Lights should turn off after five minutes 3 If lights still do not turn off call 800 879 8585 for technical support Re adjusting the Time out Period To re adjust the time out period set the new time delay in the user settings If this is done while the timer is counting down a prior setting the new setting will not be recognized unt...

Page 6: ...N WARRANTY INFORMATION WattStopper warranties its products to be free of defects in materials and workmanship for a period of five years There are no obligations or liabilities on the part of WattStopper for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of remova...

Reviews: