User Manual
48
The wattsonic WTS-[25-50kW]-100A-3P hybrid inverter supports WIFI, LAN, and 4G communication.
Plug the WIFI, LAN, or 4G module into the COM1 port at the bottom of the inverter. A slight “click” sound during the
installation indicates the assembly is in place.
4.5 Monitoring device installation
Note
:
Please
refer to “7 Monitoring” for more information.
The current Transformer, also called CT, is usually installed on the L wires between the house loads and the power grid.
The Meter can be installed in the AC combiner box or other places that are unable to be touched by children. Wattsonic
CT cable with a length of 2m is fixed and can not be extended.
The CTs were connected to the Wattsonic Meter when you received them, and you need to follow the wiring diagram in
the Meter to join the CT.
4.6 Meter and CT connection
002456
UTILITY METER
FOR BILLING
PURPOSES
UTILITY
GRID
L1
L2
L3
N
PE
CT
-2
CT
-3
CT
-1
S1(Red)
AC
Br
ea
ke
r
AC
Br
ea
ke
r
Mete
r
T
o Solinteg
Mete
r
Hou
se
G
rid
The direction of t
he a
rrow is
consistent with the direction of
the arrow inside the CT.
S2(Yellow)