background image

IS-TK-DL

Installation

The Watts TK-DL Computerized Backfl ow Tester

 is an advanced piece of test equipment designed to make pressure and differ-

ential gauges obsolete in the testing of backfl ow assemblies. Two solid-state, high-resolution pressure transducers provide the inter-
face to the computer. With 32K of memory, battery back up, 48 character super-twist display, 16 function keyboard and high-effi cien-
cy thermal printer, the TK-DL is equipped to provide real time data handling and the outputs required to test, validate and certify every 
backfl ow assembly. (See operating manual for details).  The TK-DL allows you to download your test results into a personal computer 
for permanent storage. In addition, the TK-DL menu driven software program allows for customizing of printed header and footer.

GENERAL INFORMATION
Before connecting hoses to tester, be sure to fl ush test cocks on backfl ow assembly.

CAUTION:  To avoid freeze damage to the test kit, it should be stored in a dry warm area when not in use.

Watts TK-DL
(in carrying case - sold separately)

Watts TK-DL

Limited Warranty:

 Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of 

original shipment.  In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.  

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.  THE COMPANY MAKES NO OTHER 
WARRANTIES, EXPRESS OR IMPLIED.  THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special 
or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 
from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no 
control.  This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.  
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages.  Therefore the above 
limitations may not apply to you.  This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State.  You should consult applicable state laws to 
determine your rights.  

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Watts TK-DL

Digital Print-out Test Kit for Backfl ow Preventer Assemblies

IS-TK-DL.indd   1

9/5/08   2:18:57 PM

Summary of Contents for TK-DL

Page 1: ...COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and the Company shall not ...

Page 2: ...then TC 2 Bleed hose then close VA 3 Close shutoff valve 2 then 1 Push Print Head wait then Push Start Test 4 Slowly open VA when air inlet float opens push hold but ton for at least 2 seconds Record differential reading must be 1 PSID or more Close VA Push Stop Test 5 Close TC 2 and remove hose 6 Open shutoff valve 1 Test No 2 Test Check Valve 7 Install highside hose between TC 1 and tester connec...

Page 3: ...hree turns 8 When dripping from bleed screw stops and gauge reading settles this is the check differential This must be 1 PSI or greater 9 Press PAUSE STOP button Test No 2 Air Inlet Vent Opening 10 Press START TEST RESUME 11 Slowly open VA and watch vent with finger over DISPLAY HOLD button When the water level above the vent starts to drop this is the vent opening press DISPLAY HOLD button This w...

Page 4: ...ecord as tight If reading returns to 0 and the pressure A increases to pressure B the check is recorded as leaking If the reading returns to PSID No 2 shutoff valve is leaking excessively and must be replaced to test the valve 8 Close all test cocks remove hoses from TC 2 and TC 3 and TC 1 reopen shutoff valve 1 Proceed to Test No 2 Push Stop Test Test No 2 Test No 2 Check Valve 1 Install high sid...

Page 5: ...ed air by loosening hose connection at VA Tighten hose connection and close VB Push Print Head wait then Push Start Test 7 Open VA then slowly open VB no more than 1 4 turn When relief valve drips push the hold button for 2 seconds Record reading must be 2 PSID or more Push Stop Test 8 Close VA and VB Test No 2 Test No 2 Check Valve 9 Install bypass hose between VA and TC 4 Open VA then bleed air ...

Page 6: ...ssemble and replace seat o ring d Damaged guide holding Disassemble clean or replace check open e Weak or broken spring Disassemble and replace spring 2 Chatter during flow a Worn damaged or Disassemble and repair or conditions defective guide replace guide 3 Low flows passing a Mainline check fouled Disassemble and clean through mainline valve 709DCDA only b Meter strainer plugged Disassemble and c...

Page 7: ... valve seat or inlet cover Install dielectric unions Watts Series 3001 through 3006 Electrically ground the piping system and or electrically isolate the device with plastic pipe immediately upstream and downstream of the device B 6 Valve improperly reassembled No B 6 If valve is diassembled during installation caution must be exercised to install check springs in their proper location C Valve exh...

Page 8: ...ou can then load into the TK DL when you are connected to the computer After loading you must write data to tester Step F H Load Footing File Same as load heading except for footer G H Brings up headers and footers that were pro grammed and saved at an earlier time You may recall the footer or header to program into you test kit The recalled or Loaded information will overwrite current information...